Datasheet
PIC24HJ32GP302/304, PIC24HJ64GPX02/X04 AND PIC24HJ128GPX02/X04
DS70293G-page 350 © 2007-2012 Microchip Technology Inc.
29.2 AC Characteristics and Timing
Parameters
The information contained in this section defines
PIC24HJ32GP302/304, PIC24HJ64GPX02/X04 and
PIC24HJ128GPX02/X04 AC characteristics and timing
parameters for high temperature devices. However, all
AC timing specifications in this section are the same as
those in Section 28.2 “AC Characteristics and
Timing Parameters”, with the exception of the
parameters listed in this section.
Parameters in this section begin with an H, which
denotes High temperature. For example, parameter
OS53 in Section 28.2 “AC Characteristics and
Timing Parameters” is the Industrial and Extended
temperature equivalent of HOS53.
TABLE 29-8: TEMPERATURE AND VOLTAGE SPECIFICATIONS – AC
FIGURE 29-1: LOAD CONDITIONS FOR DEVICE TIMING SPECIFICATIONS
TABLE 29-9: PLL CLOCK TIMING SPECIFICATIONS
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature -40°C ≤ TA ≤ +150°C for High Temperature
Operating voltage V
DD range as described in Table 29-1.
VDD/2
C
L
RL
Pin
Pin
V
SS
VSS
CL
RL =464Ω
C
L = 50 pF for all pins except OSC2
15 pF for OSC2 output
Load Condition 1
– for all pins except OSC2 Load Condition 2 – for OSC2
AC
CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V (unless otherwise stated)
Operating temperature -40°C ≤ TA ≤ +150°C for High Temperature
Param
No.
Symbol Characteristic Min Typ Max Units Conditions
HOS53 D
CLK CLKO Stability (Jitter)
(1)
-5 0.5 5 % Measured over 100 ms
period