Datasheet

2010 Microchip Technology Inc. DS39940D-page 251
PIC24FJ64GB004 FAMILY
FIGURE 20-2: ALARM MASK SETTINGS
Note 1: Annually, except when configured for February 29.
s
ss
mss
mm s s
hh mm ss
dhhmmss
dd hh mm s s
mm d d h h mm s s
Day of
the
Week
Month Day Hours Minutes Seconds
Alarm Mask Setting
(AMASK<3:0>)
0000 - Every half second
0001 - Every second
0010 - Every 10 seconds
0011 - Every minute
0100 - Every 10 minutes
0101 - Every hour
0110 - Every day
0111 - Every week
1000 - Every month
1001 - Every year
(1)