Datasheet
PIC24FJ128GA310 FAMILY
DS39996F-page 208 2010-2011 Microchip Technology Inc.
REGISTER 14-2: ICxCON2: INPUT CAPTURE x CONTROL REGISTER 2
U-0 U-0 U-0 U-0 U-0 U-0 U-0 R/W-0
— — — — — — —IC32
bit 15 bit 8
R/W-0 R/W-0 HS U-0 R/W-0 R/W-1 R/W-1 R/W-0 R/W-1
ICTRIG TRIGSTAT
— SYNCSEL4 SYNCSEL3 SYNCSEL2 SYNCSEL1 SYNCSEL0
bit 7 bit 0
Legend: HS = Hardware Settable bit
R = Readable bit W = Writable bit U = Unimplemented bit, read as ‘0’
-n = Value at POR ‘1’ = Bit is set ‘0’ = Bit is cleared x = Bit is unknown
bit 15-9 Unimplemented: Read as ‘0’
bit 8 IC32: Cascade Two IC Modules Enable bit (32-bit operation)
1 = ICx and ICy operate in cascade as a 32-bit module (this bit must be set in both modules)
0 = ICx functions independently as a 16-bit module
bit 7 ICTRIG: ICx Sync/Trigger Select bit
1 = Trigger ICx from the source designated by the SYNCSELx bits
0 = Synchronize ICx with the source designated by the SYNCSELx bits
bit 6 TRIGSTAT: Timer Trigger Status bit
1 = Timer source has been triggered and is running (set in hardware, can be set in software)
0 = Timer source has not been triggered and is being held clear
bit 5 Unimplemented: Read as ‘0’
Note 1: Use these inputs as trigger sources only and never as sync sources.
2: Never use an IC module as its own trigger source, by selecting this mode.