TABLE 4-10: 6-OUTPUT PWM1 REGISTER MAP
SFR Name Addr. Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Reset State
P1TCON 01C0 PTEN
—PTSIDL PTOPS<3:0> PTCKPS<1:0> PTMOD<1:0>
0000 0000 0000 0000
P1TMR 01C2 PTDIR PWM Timer Count Value Register
0000 0000 0000 0000
P1TPER 01C4 PWM Time Base Period Register
0111 1111 1111 1111
P1SECMP 01C6 SEVTDIR PWM Special Event Compare Register
0000 0000 0000 0000
PWM1CON1
01C8 —PMOD3PMOD2PMOD1 PEN3H PEN2H PEN1H PEN3L PEN2L PEN1L
0000 0000 0000 0000
PWM1CON2
01CA —SEVOPS<3:0> IUE OSYNC UDIS
0000 0000 0000 0000
P1DTCON1 01CC DTBPS<1:0> DTB<5:0> DTAPS<1:0> DTA<5:0>
0000 0000 0000 0000
P1DTCON2 01CE DTS3A DTS3I DTS2A DTS2I DTS1A DTS1I
0000 0000 0000 0000
P1FLTACON 01D0 FAOV3H FAOV3L FAOV2H FAOV2L FAOV1H FAOV1L FLTAM FAEN3 FAEN2 FAEN1
0000 0000 0000 0111
P1FLTBCON 01D2 FBOV3H FBOV3L FBOV2H FBOV2L FBOV1H FBOV1L FLTBM FBEN3 FBEN2 FBEN1
0000 0000 0000 0111
P1OVDCON 01D4 POVD3H POVD3L POVD2H POVD2L POVD1H POVD1L POUT3H POUT3L POUT2H POUT2L POUT1H POUT1L
0011 1111 0000 0000
P1DC1 01D6 PWM Duty Cycle 1 Register
0000 0000 0000 0000
P1DC2 01D8 PWM Duty Cycle 2 Register
0000 0000 0000 0000
P1DC3 01DA PWM Duty Cycle 3 Register
0000 0000 0000 0000
PWM1KEY 01DE PWMLOCK<15:0>
0000 0000 0000 0000
Legend: u = uninitialized bit, — = unimplemented, read as ‘0
TABLE 4-11: I2C1 REGISTER MAP
SFR Name
SFR
Addr
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1Bit 0
All
Resets
I2C1RCV 0200 Receive Register
0000
I2C1TRN 0202 Transmit Register
00FF
I2C1BRG 0204 Baud Rate Generator Register
0000
I2C1CON 0206 I2CEN I2CSIDL SCLREL IPMIEN A10M DISSLW SMEN GCEN STREN ACKDT ACKEN RCEN PEN RSEN SEN
1000
I2C1STAT 0208 ACKSTAT TRSTAT BCL GCSTAT ADD10 IWCOL I2COV D_A P S R_W RBF TBF
0000
I2C1ADD 020A Address Register
0000
I2C1MSK 020C Address Mask Register
0000
Legend: x = unknown value on Reset, — = unimplemented, read as ‘0’. Reset values are shown in hexadecimal.