Datasheet
© 2011-2012 Microchip Technology Inc. Preliminary DS39997C-page 277
PIC24FJ16MC101/102 AND PIC24FJ32MC101/102/104
FIGURE 26-9: MOTOR CONTROL PWM MODULE FAULT TIMING CHARACTERISTICS
FIGURE 26-10: MOTOR CONTROL PWM MODULE TIMING CHARACTERISTICS
FLTA1
PWMx
MP30
MP20
See Note 1
Note 1: For the logic state after a Fault, refer to the FAOVxH:FAOVxL bits in the PxFLTACON register.
PWMx
MP11 MP10
Note: Refer to Figure 26-1 for load conditions.
TABLE 26-28: MOTOR CONTROL PWM MODULE TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature -40°C ≤ TA ≤ +85°C for Industrial
-40°C ≤ TA ≤ +125°C for Extended
Param
No.
Symbol Characteristic
(1)
Min Typ Max Units Conditions
MP10 TFPWM PWM Output Fall Time — — — ns See parameter DO32
MP11 T
RPWM PWM Output Rise Time — — — ns See parameter DO31
MP20
T
FD Fault Input ↓ to PWM
I/O Change
——50ns —
MP30 TFH Minimum Pulse Width 50 — — ns —
Note 1: These parameters are characterized by similarity, but are not tested in manufacturing.