Datasheet
© 2011-2012 Microchip Technology Inc. Preliminary DS39997C-page 269
PIC24FJ16MC101/102 AND PIC24FJ32MC101/102/104
FIGURE 26-2: EXTERNAL CLOCK TIMING
Q1 Q2 Q3 Q4
OSC1
CLKO
Q1 Q2 Q3 Q4
OS20
OS25
OS30 OS30
OS40
OS41
OS31 OS31
TABLE 26-16: EXTERNAL CLOCK TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature -40°C ≤ TA ≤ +85°C for Industrial
-40°C ≤ T
A ≤ +125°C for Extended
Param
No.
Symb Characteristic Min Typ
(1)
Max Units Conditions
OS10 FIN External CLKI Frequency
(External clocks allowed only
in EC and ECPLL modes)
DC — 32 MHz EC
Oscillator Crystal Frequency 3.0
10
31
—
—
—
10
32
33
MHz
MHz
kHz
MS
HS
SOSC
OS20 TOSC TOSC = 1/FOSC 31.25 — DC ns —
OS25 T
CY Instruction Cycle Time
(2,4)
62.5 — DC ns —
OS30 TosL,
TosH
External Clock in (OSC1)
(5)
High or Low Time
0.45 x TOSC ——nsEC
OS31 TosR,
TosF
External Clock in (OSC1)
(5)
Rise or Fall Time
——20nsEC
OS40 TckR CLKO Rise Time
(3,5)
—610ns—
OS41 TckF CLKO Fall Time
(3,5)
—610ns—
OS42 GM External Oscillator
Transconductance
(4)
14 16 18 mA/V VDD = 3.3V
T
A = +25ºC
Note 1: Data in “Typ” column is at 3.3V, 25°C unless otherwise stated.
2: Instruction cycle period (TCY) equals two times the input oscillator time-base period. All specified values
are based on characterization data for that particular oscillator type under standard operating conditions
with the device executing code. Exceeding these specified limits may result in an unstable oscillator
operation and/or higher than expected current consumption. All devices are tested to operate at “min.”
values with an external clock applied to the OSC1/CLKI pin. When an external clock input is used, the
“max.” cycle time limit is “DC” (no clock) for all devices.
3: Measurements are taken in EC mode. The CLKO signal is measured on the OSC2 pin.
4: These parameters are characterized by similarity, but are tested in manufacturing at F
IN = 32 MHz only.
5: These parameters are characterized by similarity, but are not tested in manufacturing.
6: Data for this parameter is Preliminary. This parameter is characterized, but not tested in manufacturing.