Datasheet

2008-2011 Microchip Technology Inc. DS39927C-page 169
PIC24F16KA102 FAMILY
20.3 Registers
There are four registers used to control programmable
CRC operation:
CRCCON
CRCXOR
CRCDAT
CRCWDAT
REGISTER 20-1: CRCCON: CRC CONTROL REGISTER
U-0 U-0 R/W-0 R-0, HSC R-0, HSC R-0, HSC R-0, HSC R-0, HSC
CSIDL VWORD4 VWORD3 VWORD2 VWORD1 VWORD0
bit 15 bit 8
R-0, HSC R-1, HSC U-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0
CRCFUL CRCMPT
CRCGO PLEN3 PLEN2 PLEN1 PLEN0
bit 7 bit 0
Legend: HSC = Hardware Settable/Clearable bit
R = Readable bit W = Writable bit U = Unimplemented bit, read as ‘0’
-n = Value at POR ‘1’ = Bit is set ‘0’ = Bit is cleared x = Bit is unknown
bit 15-14 Unimplemented: Read as ‘0
bit 13 CSIDL: CRC Stop in Idle Mode bit
1 = Discontinue module operation when device enters Idle mode
0 = Continue module operation in Idle mode
bit 12-8 VWORD<4:0>: Pointer Value bits
Indicates the number of valid words in the FIFO. Has a maximum value of 8 when PLEN<3:0> > 7, or
16 when PLEN<3:0>
7.
bit 7 CRCFUL: FIFO Full bit
1 = FIFO is full
0 = FIFO is not full
bit 6 CRCMPT: FIFO Empty Bit
1 = FIFO is empty
0 = FIFO is not empty
bit 5 Unimplemented: Read as ‘0
bit 4 CRCGO: Start CRC bit
1 = Start CRC serial shifter
0 = CRC serial shifter is turned off
bit 3-0 PLEN<3:0>: Polynomial Length bits
Denotes the length of the polynomial to be generated minus 1.