Datasheet
PIC24F16KL402 FAMILY
DS30001037C-page 224 2011-2013 Microchip Technology Inc.
TABLE 26-36: A/D CONVERSION TIMING REQUIREMENTS
(1)
AC CHARACTERISTICS
Standard Operating Conditions: 1.8V to 3.6V
(unless otherwise stated)
Operating temperature -40°C T
A +85°C for Industrial
Param
No.
Symbol Characteristic Min. Typ Max. Units Conditions
Clock Parameters
AD50 T
AD A/D Clock Period 75 — — ns TCY = 75 ns, AD1CON3
is in default state
AD51 T
RC A/D Internal RC Oscillator Period — 250 — ns
Conversion Rate
AD55 T
CONV Conversion Time — 12 — TAD
AD56 FCNV Throughput Rate — — 500 ksps AVDD 2.7V
AD57 TSAMP Sample Time — 1 — TAD
AD58 TACQ Acquisition Time 750 — — ns (Note 2)
AD59 TSWC Switching Time from Convert to
Sample
——(Note 3) —
AD60 T
DIS Discharge Time 0.5 — — TAD
Clock Parameters
AD61 TPSS Sample Start Delay from Setting
Sample bit (SAMP)
2— 3 TAD
Note 1: Because the sample caps will eventually lose charge, clock rates below 10 kHz can affect linearity
performance, especially at elevated temperatures.
2: The time for the holding capacitor to acquire the “New” input voltage when the voltage changes full scale
after the conversion (V
DD to VSS or VSS to VDD).
3: On the following cycle of the device clock.