Datasheet

2011-2013 Microchip Technology Inc. DS30001037C-page 219
PIC24F16KL402 FAMILY
FIGURE 26-11: I
2
C™ BUS START/STOP BITS TIMING
TABLE 26-31: I
2
C™ BUS START/STOP BITS REQUIREMENTS (SLAVE MODE)
FIGURE 26-12: I
2
C™ BUS DATA TIMING
Param.
No.
Symbol Characteristic Min Max Units Conditions
90 T
SU:STA Start Condition 100 kHz mode 4700 ns Only relevant for Repeated
Start condition
Setup Time 400 kHz mode 600
91 THD:STA Start Condition 100 kHz mode 4000 ns After this period, the first
clock pulse is generated
Hold Time 400 kHz mode 600
92 T
SU:STO Stop Condition 100 kHz mode 4700 ns
Setup Time 400 kHz mode 600
93 T
HD:STO Stop Condition 100 kHz mode 4000 ns
Hold Time 400 kHz mode 600
Note: Refer to Figure 26-3 for load conditions.
SCLx
SDAx
Start
Condition
Stop
Condition
91
90
93
92
Note: Refer to Figure 26-3 for load conditions.
90
91 92
100
101
103
106
107
109 109
110
102
SCLx
SDAx
In
SDAx
Out