Datasheet

2011 Microchip Technology Inc. DS39960D-page 499
PIC18F87K22 FAMILY
TABLE 31-1: MEMORY PROGRAMMING REQUIREMENTS
DC CHARACTERISTICS
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C TA +85°C for industrial
-40°C
TA +125°C for extended
Param
No.
Sym Characteristic Min Typ† Max Units Conditions
Internal Program Memory
Programming Specifications
(1)
D110
V
PP Voltage on MCLR/VPP/RE5 pin VDD + 1.5 10 V (Note 3, Note 4)
D113 IDDP Supply Current during
Programming
——10mA
Data EEPROM Memory (Note 2)
D120 ED Byte Endurance 100K E/W -40C to +125C
D121 V
DRW VDD for Read/Write 1.8 5.5 V Using EECON to read/
write, ENVREG tied to V
DD
1.8 3.6 V Using EECON to read/
write, ENVREG tied to V
SS
D122 TDEW Erase/Write Cycle Time 4 ms
D123 T
RETD Characteristic Retention 40 Year Provided no other
specifications are violated
D124 T
REF Number of Total Erase/Write
Cycles before Refresh
(2)
1M 10M E/W -40°C to +125°C
Program Flash Memory
D130 EP Cell Endurance 10K E/W -40C to +125C
D131 V
PR VDD for Read 1.8 5.5 V ENVREG tied to VDD
1.8 3.6 V ENVREG tied to VSS
D132B VPEW Voltage for Self-Timed Erase or
Write Operations
V
DD 1.8 5.5 V ENVREG tied to VDD
D133A TIW Self-Timed Write Cycle Time 2 ms
D134 T
RETD Characteristic Retention 40 Year Provided no other
specifications are violated
D135 I
DDP Supply Current during
Programming
——10mA
D140 T
WE Writes per Erase Cycle 1 For each physical address
Data in “Typ” column is at 3.3V, 25°C unless otherwise stated. These parameters are for design guidance
only and are not tested.
Note 1: These specifications are for programming the on-chip program memory through the use of table write
instructions.
2: Refer to Section 9.8 “Using the Data EEPROM” for a more detailed discussion on data EEPROM
endurance.
3: Required only if Single-Supply Programming is disabled.
4: The MPLAB
®
ICD 2 does not support variable VPP output. Circuitry to limit the MPLAB ICD 2 VPP voltage
must be placed between the MPLAB ICD 2 and the target system when programming or debugging with
the MPLAB ICD 2.