Datasheet
PIC18F6310/6410/8310/8410
DS39635C-page 252 2010 Microchip Technology Inc.
19.3.2 AUSART SYNCHRONOUS
MASTER RECEPTION
Once Synchronous mode is selected, reception is
enabled by setting either the Single Receive Enable bit,
SREN (RCSTA2<5>), or the Continuous Receive
Enable bit, CREN (RCSTA2<4>). Data is sampled on
the RX2 pin on the falling edge of the clock.
If enable bit, SREN, is set, only a single word is
received. If enable bit, CREN, is set, the reception is
continuous until CREN is cleared. If both bits are set,
then CREN takes precedence.
To set up a Synchronous Master Reception:
1. Initialize the SPBRG2 register for the appropriate
baud rate.
2. Enable the synchronous master serial port by
setting bits, SYNC, SPEN and CSRC.
3. Ensure bits, CREN and SREN, are clear.
4. If interrupts are desired, set enable bit, RC2IE.
5. If 9-bit reception is desired, set bit, RX9.
6. If a single reception is required, set bit, SREN.
For continuous reception, set bit, CREN.
7. Interrupt flag bit, RC2IF, will be set when
reception is complete and an interrupt will be
generated if the enable bit, RC2IE, was set.
8. Read the RCSTA2 register to get the 9th bit (if
enabled) and determine if any error occurred
during reception.
9. Read the 8-bit received data by reading the
RCREG2 register.
10. If any error occurred, clear the error by clearing
bit, CREN.
11. If using interrupts, ensure that the GIE and PEIE
bits in the INTCON register (INTCON<7:6>) are
set.
FIGURE 19-8: SYNCHRONOUS RECEPTION (MASTER MODE, SREN)
TABLE 19-7: REGISTERS ASSOCIATED WITH SYNCHRONOUS MASTER RECEPTION
Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Reset
Values
on Page
INTCON GIE/GIEH PEIE/GIEL
TMR0IE INT0IE RBIE TMR0IF INT0IF RBIF 63
PIR3
— — RC2IF TX2IF — — — CCP3IF 65
PIE3
— — RC2IE TX2IE — — — CCP3IE 65
IPR3
— — RC2IP TX2IP — — — CCP3IP 65
RCSTA2 SPEN RX9 SREN CREN
ADDEN FERR OERR RX9D 66
RCREG2 AUSART2 Receive Register 66
TXSTA2 CSRC
TX9 TXEN SYNC — BRGH TRMT TX9D 66
SPBRG2 AUSART2 Baud Rate Generator Register Low Byte 66
Legend: — = unimplemented, read as ‘0’. Shaded cells are not used for synchronous master reception.
CREN bit
RX2/DT2 Pin
TX2/CK2 Pin
Write to
bit SREN
SREN bit
RC2IF bit
(Interrupt)
Read
RCREG2
Q3 Q4 Q1 Q2 Q3 Q4 Q1 Q2 Q3 Q4Q2 Q1 Q2 Q3 Q4 Q1 Q2 Q3 Q4 Q1 Q2 Q3 Q4 Q1 Q2 Q3 Q4 Q1Q2 Q3 Q4 Q1 Q2 Q3 Q4 Q1 Q2 Q3 Q4
‘
0
’
bit 0 bit 1 bit 2 bit 3 bit 4 bit 5 bit 6 bit 7
‘
0
’
Q1 Q2 Q3 Q4
Note: Timing diagram demonstrates Sync Master mode with bit SREN = 1 and bit BRGH = 0.