Datasheet
PIC18F2X1X/4X1X
DS39636D-page 322 © 2009 Microchip Technology Inc.
Supply Current (IDD)
(2,3)
All devices 7.5 16 mA -40°C
V
DD = 4.2V
F
OSC = 4 MHZ
(PRI_RUN HS+PLL)
7.4 15 mA +25°C
7.3 14 mA +85°C
Extended devices only 8.0 25 mA +125°C
All devices 10 21 mA -40°C
V
DD = 5.0V
F
OSC = 4 MHZ
(PRI_RUN HS+PLL)
10 20 mA +25°C
9.7 19 mA +85°C
Extended devices only 10 35 mA +125°C
All devices 17 35 mA -40°C
V
DD = 4.2V
F
OSC = 10 MHZ
(PRI_RUN HS+PLL)
17 35 mA +25°C
17 35 mA +85°C
All devices 23 40 mA -40°C
V
DD = 5.0V
F
OSC = 10 MHZ
(PRI_RUN HS+PLL)
23 40 mA +25°C
23 40 mA +85°C
25.2 DC Characteristics: Power-Down and Supply Current
PIC18F2X1X/4X1X (Industrial)
PIC18LF2X1X/4X1X (Industrial) (Continued)
PIC18LF2X1X/4X1X
(Industrial)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C ≤ T
A ≤ +85°C for industrial
PIC18F2X1X/4X1X
(Industrial, Extended)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C ≤ T
A ≤ +85°C for industrial
-40°C ≤ T
A ≤ +125°C for extended
ParamNo. Device Typ Max Units Conditions
Legend: Shading of rows is to assist in readability of the table.
Note 1: The power-down current in Sleep mode does not depend on the oscillator type. Power-down current is measured
with the part in Sleep mode, with all I/O pins in high-impedance state and tied to V
DD or VSS and all features that
add delta current disabled (such as WDT, Timer1 Oscillator, BOR, etc.).
2: The supply current is mainly a function of operating voltage, frequency and mode. Other factors, such as I/O pin
loading and switching rate, oscillator type and circuit, internal code execution pattern and temperature, also have
an impact on the current consumption.
The test conditions for all I
DD measurements in active operation mode are:
OSC1 = external square wave, from rail-to-rail; all I/O pins tri-stated, pulled to V
DD;
MCLR
= VDD; WDT enabled/disabled as specified.
3: For RC oscillator configurations, current through R
EXT is not included. The current through the resistor can be
estimated by the formula Ir = V
DD/2REXT (mA) with REXT in kΩ.
4: Low-power Timer1 oscillator selected.
5: BOR and HLVD enable internal band gap reference. With both modules enabled, current consumption will be less
than the sum of both specifications.