Datasheet
PIC18F45J10 FAMILY
DS39682E-page 330 © 2009 Microchip Technology Inc.
TABLE 24-19: I
2
C™ BUS DATA REQUIREMENTS (SLAVE MODE)
Param.
No.
Symbol Characteristic Min Max Units Conditions
100 T
HIGH Clock High Time 100 kHz mode 4.0 — μs
400 kHz mode 0.6 — μs
MSSP Module 1.5 T
CY —
101 T
LOW Clock Low Time 100 kHz mode 4.7 — μs
400 kHz mode 1.3 — μs
MSSP Module 1.5 T
CY —
102 T
R SDAx and SCLx Rise Time 100 kHz mode — 1000 ns
400 kHz mode 20 + 0.1 C
B 300 ns CB is specified to be from
10 to 400 pF
103 T
F SDAx and SCLx Fall Time 100 kHz mode — 300 ns
400 kHz mode 20 + 0.1 C
B 300 ns CB is specified to be from
10 to 400 pF
90 T
SU:STA Start Condition Setup Time 100 kHz mode 4.7 — μs Only relevant for Repeated
Start condition
400 kHz mode 0.6 — μs
91 T
HD:STA Start Condition Hold Time 100 kHz mode 4.0 — μs After this period, the first clock
pulse is generated
400 kHz mode 0.6 — μs
106 T
HD:DAT Data Input Hold Time 100 kHz mode 0 — ns
400 kHz mode 0 0.9 μs
107 T
SU:DAT Data Input Setup Time 100 kHz mode 250 — ns (Note 2)
400 kHz mode 100 — ns
92 T
SU:STO Stop Condition Setup Time 100 kHz mode 4.7 — μs
400 kHz mode 0.6 — μs
109 T
AA Output Valid from Clock 100 kHz mode — 3500 ns (Note 1)
400 kHz mode — — ns
110 T
BUF Bus Free Time 100 kHz mode 4.7 — μs Time the bus must be free
before a new transmission can
start
400 kHz mode 1.3 — μs
D102 C
B Bus Capacitive Loading — 400 pF
Note 1: As a transmitter, the device must provide this internal minimum delay time to bridge the undefined region (min. 300 ns)
of the falling edge of SCLx to avoid unintended generation of Start or Stop conditions.
2: A Fast mode I
2
C™ bus device can be used in a Standard mode I
2
C bus system, but the requirement, TSU:DAT ≥ 250 ns,
must then be met. This will automatically be the case if the device does not stretch the LOW period of the SCLx signal.
If such a device does stretch the LOW period of the SCLx signal, it must output the next data bit to the SDAx line,
T
R max. + TSU:DAT = 1000 + 250 = 1250 ns (according to the Standard mode I
2
C bus specification), before the SCLx
line is released.