27.2 DC Characteristics: Power-Down and Supply Current
PIC18F2585/2680/4585/4680 (Industrial)
PIC18LF2585/2680/4585/4680 (Industrial)
PIC18LF2585/2680/4585/4680
(Industrial)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C T
A +85°C for industrial
PIC18F2585/2680/4585/4680
(Industrial, Extended)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C T
A +85°C for industrial
-40°C T
A +125°C for extended
Param
No.
Device Typ Max Units Conditions
Power-down Current (I
PD)
(1)
PIC18LFX585/X680 0.25 0.95 μA -40°C
V
DD = 2.0V,
(Sleep mode)
0.3 1.0 μA +25°C
3.0 6.0 μA +85°C
PIC18LFX585/X680 0.3 1.4 μA -40°C
V
DD = 3.0V,
(Sleep mode)
0.35 2.0 μA +25°C
3.5 8.0 μA +85°C
All devices 0.5 1.9 μA -40°C
V
DD = 5.0V,
(Sleep mode)
0.5 2.0 μA +25°C
6.0 15 μA +85°C
PIC18FX585/X680 10.00 120.00 μA +125°C
Legend: Shading of rows is to assist in readability of the table.
Note 1: The power-down current in Sleep mode does not depend on the oscillator type. Power-down current is measured with the
part in Sleep mode, with all I/O pins in high-impedance state and tied to V
DD or VSS and all features that add delta current
disabled (such as WDT, Timer1 Oscillator, BOR, etc.).
2: The supply current is mainly a function of operating voltage, frequency and mode. Other factors, such as I/O pin loading
and switching rate, oscillator type and circuit, internal code execution pattern and temperature, also have an impact on
the current consumption. The test conditions for all I
DD measurements in active operation mode are:
OSC1 = external square wave, from rail-to-rail; all I/O pins tri-stated, pulled to V
DD;
MCLR
= VDD; WDT enabled/disabled as specified.
3: For RC oscillator configurations, current through R
EXT is not included. The current through the resistor can be estimated
by the formula Ir = V
DD/2REXT (mA) with REXT in kΩ.
4: Standard low-cost 32 kHz crystals have an operating temperature range of -10°C to +70°C. Extended temperature
crystals are available at a much higher cost.