Datasheet
© 2009 Microchip Technology Inc. DS39632E-page 397
PIC18F2455/2550/4455/4550
FIGURE 28-15: I
2
C™ BUS START/STOP BITS TIMING
TABLE 28-19: I
2
C™ BUS START/STOP BITS REQUIREMENTS (SLAVE MODE)
FIGURE 28-16: I
2
C™ BUS DATA TIMING
Note: Refer to Figure 28-4 for load conditions.
91
92
93
SCL
SDA
Start
Condition
Stop
Condition
90
Param.
No.
Symbol Characteristic Min Max Units Conditions
90 T
SU:STA Start Condition 100 kHz mode 4700 — ns Only relevant for Repeated
Start condition
Setup Time 400 kHz mode 600 —
91 T
HD:STA Start Condition 100 kHz mode 4000 — ns After this period, the first
clock pulse is generated
Hold Time 400 kHz mode 600 —
92 TSU:STO Stop Condition 100 kHz mode 4700 — ns
Setup Time 400 kHz mode 600 —
93 T
HD:STO Stop Condition 100 kHz mode 4000 — ns
Hold Time 400 kHz mode 600 —
Note: Refer to Figure 28-4 for load conditions.
90
91 92
100
101
103
106
109
109
110
102
SCL
SDA
In
SDA
Out
107