Supply Current (IDD)
(2)
PIC18LFX455/X550 2.9 8 μA-40°C
V
DD = 2.0V
F
OSC = 31 kHz
(RC_IDLE mode,
INTRC source)
3.1 8 μA+25°C
3.6 11 μA+85°C
PIC18LFX455/X550 4.5 11 μA-40°C
V
DD = 3.0V4.8 11 μA+25°C
5.8 15 μA+85°C
All devices 9.2 16 μA-40°C
V
DD = 5.0V9.8 16 μA+25°C
11.4 36 μA+85°C
PIC18LFX455/X550 165 350 μA-40°C
V
DD = 2.0V
F
OSC = 1 MHz
(RC_IDLE mode,
INTOSC source)
175 350 μA+25°C
190 350 μA+85°C
PIC18LFX455/X550 250 500 μA-40°C
V
DD = 3.0V270 500 μA+25°C
290 500 μA+85°C
All devices 0.50 1 mA -40°C
V
DD = 5.0V0.52 1 mA +25°C
0.55 1 mA +85°C
PIC18LFX455/X550 340 500 μA-40°C
V
DD = 2.0V
F
OSC = 4 MHz
(RC_IDLE mode,
INTOSC source)
350 500 μA+25°C
360 500 μA+85°C
PIC18LFX455/X550 520 900 μA-40°C
V
DD = 3.0V540 900 μA+25°C
580 900 μA+85°C
All devices 1.0 1.6 mA -40°C
V
DD = 5.0V1.1 1.5 mA +25°C
1.1 1.4 mA +85°C
28.2 DC Characteristics: Power-Down and Supply Current
PIC18F2455/2550/4455/4550 (Industrial)
PIC18LF2455/2550/4455/4550 (Industrial) (Continued)
PIC18LF2455/2550/4455/4550
(Industrial)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C ≤ T
A ≤ +85°C for industrial
PIC18F2455/2550/4455/4550
(Industrial)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C ≤ T
A ≤ +85°C for industrial
Param
No.
Symbol Device Typ Max Units Conditions
Legend: Shading of rows is to assist in readability of the table.
Note 1: The power-down current in Sleep mode does not depend on the oscillator type. Power-down current is measured
with the part in Sleep mode, with all I/O pins in high-impedance state and tied to V
DD or VSS and all features that
add delta current disabled (such as WDT, Timer1 Oscillator, BOR, etc.).
2: The supply current is mainly a function of operating voltage, frequency and mode. Other factors, such as I/O pin
loading and switching rate, oscillator type and circuit, internal code execution pattern and temperature, also have
an impact on the current consumption.
The test conditions for all I
DD measurements in active operation mode are:
OSC1 = external square wave, from rail-to-rail; all I/O pins tri-stated, pulled to V
DD or VSS;
MCLR
= VDD; WDT enabled/disabled as specified.
3: Standard low-cost 32 kHz crystals have an operating temperature range of -10°C to +70°C. Extended
temperature crystals are available at a much higher cost.
4: BOR and HLVD enable internal band gap reference. With both modules enabled, current consumption will be