Datasheet
© 2009 Microchip Technology Inc. DS39632E-page 371
PIC18F2455/2550/4455/4550
Supply Current (IDD)
(2)
PIC18LFX455/X550 15 32 μA-40°C
VDD = 2.0V
F
OSC = 31 kHz
(RC_RUN mode,
INTRC source)
15 30 μA+25°C
15 29 μA+85°C
PIC18LFX455/X550 40 63 μA-40°C
V
DD = 3.0V35 60 μA+25°C
30 57 μA+85°C
All devices 105 168 μA-40°C
V
DD = 5.0V90 160 μA+25°C
80 152 μA+85°C
PIC18LFX455/X550 0.33 1 mA -40°C
V
DD = 2.0V
F
OSC = 1 MHz
(RC_RUN mode,
INTOSC source)
0.33 1 mA +25°C
0.33 1 mA +85°C
PIC18LFX455/X550 0.6 1.3 mA -40°C
V
DD = 3.0V0.6 1.2 mA +25°C
0.6 1.1 mA +85°C
All devices 1.1 2.3 mA -40°C
V
DD = 5.0V1.1 2.2 mA +25°C
1.0 2.1 mA +85°C
PIC18LFX455/X550 0.8 2.1 mA -40°C
V
DD = 2.0V
F
OSC = 4 MHz
(RC_RUN mode,
INTOSC source)
0.8 2.0 mA +25°C
0.8 1.9 mA +85°C
PIC18LFX455/X550 1.3 3.0 mA -40°C
V
DD = 3.0V1.3 3.0 mA +25°C
1.3 3.0 mA +85°C
All devices 2.5 5.3 mA -40°C
V
DD = 5.0V2.5 5.0 mA +25°C
2.5 4.8 mA +85°C
28.2 DC Characteristics: Power-Down and Supply Current
PIC18F2455/2550/4455/4550 (Industrial)
PIC18LF2455/2550/4455/4550 (Industrial) (Continued)
PIC18LF2455/2550/4455/4550
(Industrial)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C ≤ T
A ≤ +85°C for industrial
PIC18F2455/2550/4455/4550
(Industrial)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C ≤ T
A ≤ +85°C for industrial
Param
No.
Symbol Device Typ Max Units Conditions
Legend: Shading of rows is to assist in readability of the table.
Note 1: The power-down current in Sleep mode does not depend on the oscillator type. Power-down current is measured
with the part in Sleep mode, with all I/O pins in high-impedance state and tied to V
DD or VSS and all features that
add delta current disabled (such as WDT, Timer1 Oscillator, BOR, etc.).
2: The supply current is mainly a function of operating voltage, frequency and mode. Other factors, such as I/O pin
loading and switching rate, oscillator type and circuit, internal code execution pattern and temperature, also have
an impact on the current consumption.
The test conditions for all I
DD measurements in active operation mode are:
OSC1 = external square wave, from rail-to-rail; all I/O pins tri-stated, pulled to V
DD or VSS;
MCLR
= VDD; WDT enabled/disabled as specified.
3: Standard low-cost 32 kHz crystals have an operating temperature range of -10°C to +70°C. Extended
temperature crystals are available at a much higher cost.
4: BOR and HLVD enable internal band gap reference. With both modules enabled, current consumption will be
less than the sum of both specifications.