Datasheet
© 2008 Microchip Technology Inc. DS39631E-page 325
PIC18F2420/2520/4420/4520
26.2 DC Characteristics: Power-Down and Supply Current
PIC18F2420/2520/4420/4520 (Industrial)
PIC18LF2420/2520/4420/4520 (Industrial)
PIC18LF2420/2520/4420/4520
(Industrial)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C ≤ T
A ≤ +85°C for industrial
PIC18F2420/2520/4420/4520
(Industrial, Extended)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C ≤ T
A ≤ +85°C for industrial
-40°C ≤ T
A ≤ +125°C for extended
Param
No.
Device Typ Max Units Conditions
Power-Down Current (I
PD)
(1)
PIC18LF2X2X/4X20 0.1 0.5 μA -40°C
V
DD = 2.0V
(Sleep mode)
0.1 0.5 μA +25°C
0.2 2.5 μA +85°C
PIC18LF2X2X/4X20 0.1 0.7 μA-40°C
V
DD = 3.0V
(Sleep mode)
0.1 0.7 μA +25°C
0.3 3.5 μA +85°C
All devices 0.1 1.0 μA-40°C
V
DD = 5.0V
(Sleep mode)
0.2 1.0 μA +25°C
0.7 10 μA +85°C
Extended devices only 10 100 μA +125°C
Legend: Shading of rows is to assist in readability of the table.
Note 1: The power-down current in Sleep mode does not depend on the oscillator type. Power-down current is measured
with the part in Sleep mode, with all I/O pins in high-impedance state and tied to V
DD or VSS and all features that
add delta current disabled (such as WDT, Timer1 Oscillator, BOR, etc.).
2: The supply current is mainly a function of operating voltage, frequency and mode. Other factors, such as I/O pin
loading and switching rate, oscillator type and circuit, internal code execution pattern and temperature, also have
an impact on the current consumption.
The test conditions for all I
DD measurements in active operation mode are:
OSC1 = external square wave, from rail-to-rail; all I/O pins tri-stated, pulled to V
DD or VSS;
MCLR
= VDD; WDT enabled/disabled as specified.
3: When operation below -10°C is expected, use T1OSC High-Power mode, where LPT1OSC (CONFIG3H<2>) = 0.
When operation will always be above -10°C, then the low-power Timer1 oscillator may be selected.
4: BOR and HLVD enable internal band gap reference. With both modules enabled, current consumption will be less
than the sum of both specifications.