Datasheet
2010-2012 Microchip Technology Inc. DS39977F-page 577
PIC18F66K80 FAMILY
TABLE 31-22: MSSP I
2
C™ BUS DATA REQUIREMENTS
Param.
No.
Symbol Characteristic Min Max Units Conditions
100 THIGH Clock High
Time
100 kHz mode 2(TOSC)(BRG + 1) — —
400 kHz mode 2(T
OSC)(BRG + 1) — —
1 MHz mode
(1)
2(TOSC)(BRG + 1) — —
101 T
LOW Clock Low Time 100 kHz mode 2(TOSC)(BRG + 1) — —
400 kHz mode 2(T
OSC)(BRG + 1) — —
1 MHz mode
(1)
2(TOSC)(BRG + 1) — —
102 T
R SDA and SCL
Rise Time
100 kHz mode — 1000 ns CB is specified to be from
10 to 400 pF
400 kHz mode 20 + 0.1 C
B 300 ns
1 MHz mode
(1)
— 300 ns
103 T
F SDA and SCL
Fall Time
100 kHz mode — 300 ns CB is specified to be from
10 to 400 pF
400 kHz mode 20 + 0.1 C
B 300 ns
1 MHz mode
(1)
— 100 ns
90 T
SU:STA Start Condition
Setup Time
100 kHz mode 2(TOSC)(BRG + 1) — — Only relevant for Repeated
Start condition
400 kHz mode 2(T
OSC)(BRG + 1) — —
1 MHz mode
(1)
2(TOSC)(BRG + 1) — —
91 T
HD:STA Start Condition
Hold Time
100 kHz mode 2(TOSC)(BRG + 1) — — After this period, the first
clock pulse is generated
400 kHz mode 2(T
OSC)(BRG + 1) — —
1 MHz mode
(1)
2(TOSC)(BRG + 1) — —
106 T
HD:DAT Data Input
Hold Time
100 kHz mode 0 — —
400 kHz mode 0 0.9
s
1 MHz mode
(1)
— sns
107 T
SU:DAT Data Input
Setup Time
100 kHz mode 250 — ns (Note 2)
400 kHz mode 100 — ns
1 MHz mode
(1)
——ns
92 T
SU:STO Stop Condition
Setup Time
100 kHz mode 2(TOSC)(BRG + 1) — —
400 kHz mode 2(T
OSC)(BRG + 1) — —
1 MHz mode
(1)
2(TOSC)(BRG + 1) — —
109 T
AA Output Valid
from Clock
100 kHz mode — 3500 ns
400 kHz mode — 1000 ns
1 MHz mode
(1)
——ns
110 T
BUF Bus Free Time 100 kHz mode 4.7 — s Time the bus must be free
before a new transmission
can start
400 kHz mode 1.3 —
s
1 MHz mode
(1)
——s
D102 C
B Bus Capacitive Loading — 400 pF
Note 1: Maximum pin capacitance = 10 pF for all I
2
C™ pins.
2: A Fast mode I
2
C bus device can be used in a Standard mode I
2
C bus system, but Parameter #107 250 ns
must then be met. This will automatically be the case if the device does not stretch the LOW period of the SCL
signal. If such a device does stretch the LOW period of the SCL signal, it must output the next data bit to the
SDA line, Parameter #102 + Parameter #107 = 1000 + 250 = 1250 ns (for 100 kHz mode), before the SCL
line is released.