Datasheet
2010-2012 Microchip Technology Inc. DS39977F-page 575
PIC18F66K80 FAMILY
FIGURE 31-16: I
2
C™ BUS DATA TIMING
TABLE 31-20: I
2
C™ BUS DATA REQUIREMENTS (SLAVE MODE)
Param.
No.
Symbol Characteristic Min Max Units Conditions
100 THIGH Clock High Time 100 kHz mode 4.0 — s
400 kHz mode 0.6 —
s
MSSP module 1.5 T
CY —
101 T
LOW Clock Low Time 100 kHz mode 4.7 — s
400 kHz mode 1.3 —
s
MSSP module 1.5 T
CY —
102 T
R SDA and SCL Rise Time 100 kHz mode — 1000 ns
400 kHz mode 20 + 0.1 C
B 300 ns CB is specified to be from
10 to 400 pF
103 TF SDA and SCL Fall Time 100 kHz mode — 300 ns
400 kHz mode 20 + 0.1 C
B 300 ns CB is specified to be from
10 to 400 pF
90 TSU:STA Start Condition Setup Time 100 kHz mode 4.7 — s Only relevant for Repeated
Start condition
400 kHz mode 0.6 —
s
91 T
HD:STA Start Condition Hold Time 100 kHz mode 4.0 — s After this period, the first clock
pulse is generated
400 kHz mode 0.6 —
s
106 THD:DAT Data Input Hold Time 100 kHz mode 0 — ns
400 kHz mode 0 0.9
s
107 T
SU:DAT Data Input Setup Time 100 kHz mode 250 — ns (Note 2)
400 kHz mode 100 — ns
92 T
SU:STO Stop Condition Setup Time 100 kHz mode 4.7 — s
400 kHz mode 0.6 —
s
109 T
AA Output Valid from Clock 100 kHz mode — 3500 ns (Note 1)
400 kHz mode — — ns
110 T
BUF Bus Free Time 100 kHz mode 4.7 — s Time the bus must be free before
a new transmission can start
400 kHz mode 1.3 —
s
D102 C
B Bus Capacitive Loading — 400 pF
Note 1: As a transmitter, the device must provide this internal minimum delay time to bridge the undefined region (min. 300 ns) of
the falling edge of SCL to avoid unintended generation of Start or Stop conditions.
2: A Fast mode I
2
C™ bus device can be used in a Standard mode I
2
C bus system, but the requirement, TSU:DAT 250 ns,
must then be met. This will automatically be the case if the device does not stretch the LOW period of the SCL signal. If
such a device does stretch the LOW period of the SCL signal, it must output the next data bit to the SDA line,
T
R max. + TSU:DAT = 1000 + 250 = 1250 ns (according to the Standard mode I
2
C bus specification), before the SCL line
is released.
Note: Refer to Figure 31-3 for load conditions.
90
91 92
100
101
103
106
107
109
109
110
102
SCL
SDA
In
SDA
Out