Datasheet
2010-2012 Microchip Technology Inc. DS39977F-page 549
PIC18F66K80 FAMILY
Supply Current (IDD) Cont.
(2,3)
PIC18LFXXK80 2 5 mA -40°C to +125°C VDD = 3.3V
(4)
Regulator Disabled
F
OSC = 16 MHZ
(PRI_RUN mode, 4 MHz
EC oscillator with PLL)
PIC18FXXK80 2 5 mA -40°C to +125°C VDD = 3.3V
(5)
Regulator Enabled
PIC18FXXK80 2 6 mA -40°C to +125°C VDD = 5.5V
(5)
Regulator Enabled
PIC18L
FXXK80 7 11 mA -40°C to +125°C VDD = 3.3V
(4)
Regulator Disabled
F
OSC = 64 MHz
(
PRI_RUN mode, 16 MHz
EC oscillator with PLL)
PIC18FXXK80 7 11 mA -40°C to +125°C VDD = 3.3V
(5)
Regulator Enabled
PIC18FXXK80 8 12 mA -40°C to +125°C VDD = 5.5V
(5)
Regulator Enabled
PIC18L
FXXK80 7 11 mA -40°C to +125°C VDD = 3.3V
(4)
Regulator Disabled
F
OSC = 64 MHz
(
PRI_RUN mode,
EC oscillator)
PIC18FXXK80 7 11 mA -40°C to +125°C VDD = 3.3V
(4)
Regulator Enabled
PIC18FXXK80 8 12 mA -40°C to +125°C VDD = 5.5V
(5)
Regulator Enabled
PIC18L
FXXK80 2.3 5 mA -40°C to +125°C VDD = 3.3V
(4)
Regulator Disabled
F
OSC = 64 MHz
(
PRI_IDLE mode,
EC oscillator)
PIC18FXXK80 2.3 5 mA -40°C to +125°C VDD = 3.3V
(5)
Regulator Enabled
PIC18FXXK80 2.5 6 mA -40°C to +125°C VDD = 5.5V
(5)
Regulator Enabled
31.2 DC Characteristics: Power-Down and Supply Current
PIC18F66K80 Family (Industrial/Extended) (Continued)
PIC18F66K80 Family
(Industrial/Extended)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C TA +85°C for industrial
-40°C
TA +125°C for extended
Param
No.
Device Typ Max Units Conditions
Legend:
Shading of rows is to assist in readability of the table.
Note 1: The power-down current in Sleep mode does not depend on the oscillator type. Power-down current is measured with the
part in Sleep mode, with all I/O pins in a high-impedance state and tied to V
DD or VSS, and all features that add delta
current are disabled (such as WDT, SOSC oscillator, BOR, etc.).
2: The supply current is mainly a function of operating voltage, frequency and mode. Other factors, such as I/O pin loading
and switching rate, oscillator type and circuit, internal code execution pattern and temperature, also have an impact on the
current consumption.
The test conditions for all I
DD measurements in active operation mode are:
OSC1 = external square wave, from rail-to-rail; all I/O pins tri-stated, pulled to V
DD;
MCLR
= VDD; WDT enabled/disabled as specified.
3: Standard, low-cost 32 kHz crystals have an operating temperature range of -10°C to +70°C. Extended temperature
crystals are available at a much higher cost.
4: For LF devices, RETEN (CONFIG1L<0>) = 1.
5: For F devices, SRETEN (WDTCON<4>) = 1 and RETEN (CONFIG1L<0>) = 0.