26.5 DC Characteristics: Primary Run Supply Current, PIC18F2XK20/4XK20
PIC18F2XK20/4XK20 Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C T
A +125°C
Param
No.
Device Characteristics Typ Max Units Conditions
D014 Supply Current (I
DD)
(1, 2)
0.25 0.45 mA -40°C to +125°C VDD = 1.8V FOSC = 1 MHz
(PRI_RUN,
EC oscillator)
D014A
0.50 0.75 mA -40°C to +125°C V
DD = 3.0V
D015 2.7 3.2 mA -40°C to +125°C V
DD = 2V FOSC = 20 MHz
(PRI_RUN,
EC oscillator)
D015A
4.3 5.0 mA -40°C to +125°C V
DD = 3.0V
D016
12.2 14.0 mA -40°C to +85°C VDD = 3.0V
F
OSC = 64 MHz
(PRI_RUN,
EC oscillator)
D017 2.1 2.9 mA -40°C to +125°C V
DD = 1.8V FOSC = 4 MHz
16 MHz Internal
(PRI_RUN HS+PLL)
D017A
4.2 5.0 mA -40°C to +125°C V
DD = 3.0V
D018
12.2 15.0 mA -40°C to +85°C VDD = 3.0V
F
OSC = 16 MHz
64 MHz Internal
(PRI_RUN HS+PLL)
Note 1: The supply current is mainly a function of operating voltage, frequency and mode. Other factors, such as
I/O pin loading and switching rate, oscillator type and circuit, internal code execution pattern and
temperature, also have an impact on the current consumption.
2: The test conditions for all I
DD measurements in active operation mode are:
All I/O pins set as outputs driven to Vss;
MCLR
= VDD;
OSC1 = external square wave, from rail-to-rail (PRI_RUN and PRI_IDLE only).
26.6 DC Characteristics: Primary Idle Supply Current, PIC18F2XK20/4XK20
PIC18F2XK20/4XK20
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C T
A +125°C
Param
No.
Device Characteristics Typ Max Units Conditions
D019
Supply Current (I
DD)
(1, 2)
0.05
0.07
mA
-40°C to +125°C V
DD = 1.8V
F
OSC = 1 MHz
(PRI_IDLE mode,
EC oscillator)
D019A
0.09
0.15
mA
-40°C to +125°C V
DD = 3.0V
D020
1.2
1.6
mA
-40°C to +125°C V
DD = 2.0V
F
OSC = 20 MHz
(PRI_IDLEmode,
EC oscillator)
D020A
1.8
2.5
mA
-40°C to +125°C V
DD = 3.0V
D021
5.6
7.0
mA
-40°C to +85°C VDD = 3.0V
F
OSC = 64 MHz
(PRI_IDLEmode,
EC oscillator)
Note 1: The supply current is mainly a function of operating voltage, frequency and mode. Other factors, such as
I/O pin loading and switching rate, oscillator type and circuit, internal code execution pattern and
temperature, also have an impact on the current consumption.
2: The test conditions for all I
DD measurements in active operation mode are:
All I/O pins set as outputs driven to Vss;
MCLR
= VDD;
OSC1 = external square wave, from rail-to-rail (PRI_RUN and PRI_IDLE only).