Supply Current (IDD)
(2,3)
PIC18LF268X/468X 15 36 μA -40°C
V
DD = 2.0V
F
OSC = 31 kHz
(RC_RUN mode,
Internal oscillator source)
15 36 μA+25°C
15 36 μA+85°C
PIC18LF268X/468X 40 100 μA -40°C
V
DD = 3.0V35 100 μA+25°C
30 100 μA+85°C
All devices 105 200 μA -40°C
V
DD = 5.0V
90 200 μA+25°C
80 200 μA+85°C
Extended devices only 80 200 μA +125°C
PIC18LF268X/468X 0.32 1 mA -40°C
V
DD = 2.0V
F
OSC = 1 MHz
(RC_RUN mode,
Internal oscillator source)
0.33 1 mA +25°C
0.33 1 mA +85°C
PIC18LF268X/468X 0.6 1.6 mA -40°C
V
DD = 3.0V0.55 1.6 mA +25°C
0.6 1.6 mA +85°C
All devices 1.1 3 mA -40°C
V
DD = 5.0V
1.1 3 mA +25°C
13mA +85°C
Extended devices only 1 3 mA +125°C
PIC18LF268X/468X 0.8 2.2 mA -40°C
V
DD = 2.0V
F
OSC = 4 MHz
(RC_RUN mode,
Internal oscillator source)
0.8 2.2 mA +25°C
0.8 2.2 mA +85°C
PIC18LF268X/468X 1.3 3 mA -40°C
V
DD = 3.0V1.3 3 mA +25°C
1.3 3 mA +85°C
All devices 2.5 5.3 mA -40°C
V
DD = 5.0V
2.5 5.3 mA +25°C
2.5 5.3 mA +85°C
Extended devices only 2.5 8 mA +125°C
27.2 DC Characteristics: Power-Down and Supply Current
PIC18F2682/2685/4682/4685 (Industrial)
PIC18LF2682/2685/4682/4685 (Industrial) (Continued)
PIC18LF2682/2685/4682/4685
(Industrial)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C T
A +85°C for industrial
PIC18F2682/2685/4682/4685
(Industrial, Extended)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C T
A +85°C for industrial
-40°C T
A +125°C for extended
Param
No.
Device Typ Max Units Conditions
Legend: Shading of rows is to assist in readability of the table.
Note 1: The power-down current in Sleep mode does not depend on the oscillator type. Power-down current is measured with
the part in Sleep mode, with all I/O pins in high-impedance state and tied to V
DD or VSS and all features that add delta
current disabled (such as WDT, Timer1 Oscillator, BOR, etc.).
2: The supply current is mainly a function of operating voltage, frequency and mode. Other factors, such as I/O pin loading
and switching rate, oscillator type and circuit, internal code execution pattern and temperature, also have an impact on
the current consumption.
The test conditions for all I
DD measurements in active operation mode are:
OSC1 = external square wave, from rail-to-rail; all I/O pins tri-stated, pulled to V
DD;
MCLR
= VDD; WDT enabled/disabled as specified.
3: For RC oscillator configurations, current through R
EXT is not included. The current through the resistor can be estimated
by the formula Ir = V
DD/2REXT (mA) with REXT in kΩ.
4: Standard low-cost 32 kHz crystals have an operating temperature range of -10°C to +70°C. Extended temperature