Datasheet
2012 Microchip Technology Inc. DS30684A-page 463
PIC18(L)F2X/45K50
D015 Comparators
7718A1.8V
LP mode
7718A3.0V
7 7 18 A 2.3V
7 7 18 A 3.0V
8 8 20 A 5.0V
D16 Comparators
38 38 95 A1.8V
HP mode
40 40 105 A3.0V
39 39 95 A 2.3V
40 40 105 A 3.0V
40 40 105 A 5.0V
D017 DAC
12 12 22 A1.8V
20 20 35 A3.0V
15 15 30 A 2.3V
20 20 35 A 3.0V
32 32 60 A 5.0V
D018 FVR
(2)
15 16 25 A1.8V
15 16 25 A3.0V
28 28 45 A 2.3V
31 31 55 A 3.0V
66 66 100 A 5.0V
D013 A/D Converter
(3)
185 185 370 A1.8V
A/D on, not converting
210 210 400 A3.0V
200 200 380 A 2.3V
210 210 400 A 3.0V
250 250 450 A 5.0V
29.2 DC Characteristics: Power-Down Current, PIC18(L)F2X/45K50 (Continued)
PIC18LF2X/45K50
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C T
A +85°C
PIC18F2X/45K50
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C T
A +85°C
Param
No.
Device Characteristics
Typ
+25°C
Typ
+60°C
Max
+85°C
Units
Conditions
V
DD Notes
Note 1: The power-down current in Sleep mode does not depend on the oscillator type. Power-down current is
measured with the part in Sleep mode, with all I/O pins in high-impedance state and tied to V
DD or VSS
and all features that add delta current disabled (such as WDT, Timer1 Oscillator, BOR, etc.).
2: On LF devices, the BOR, HLVD and FVR enable internal band gap reference. With more than one of these
modules enabled, the current consumption will be less than the sum of the specifications. On F devices,
the internal band gap reference is always enabled and its current consumption is included in the Power-
down Base Current (I
PD).
3: A/D converter differential currents apply only in Run mode. In Sleep or Idle mode both the ADC and the
FRC turn off as soon as conversion (if any) is complete.