Information
© 2007 Microchip Technology Inc. DS80272B-page 3
PIC18F2585/2680/4585/4680
On page 425, the last page of the eight-page table, the
temperature is changed for the bottom row and the
punctuation fixed for the Conditions text:
27.2 DC Characteristics: Power-Down and Supply Current
PIC18F2585/2680/4585/4680 (Industrial)
PIC18LF2585/2680/4585/4680 (Industrial) (Continued)
PIC18LF2585/2680/4585/4680
(Industrial)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C ≤ T
A ≤ +85°C for industrial
PIC18F2585/2680/4585/4680
(Industrial, Extended)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C ≤ T
A ≤ +85°C for industrial
-40°C ≤ T
A ≤ +125°C for extended
Param
No.
Device Typ Max Units Conditions
D026
(ΔI
AD)
A/D Converter 1.0 2.0 μA-40°C to +85°C
V
DD = 2.0V
A/D on, not converting
1.0 2.0 μA-40°C to +85°C
V
DD = 3.0V
1.0 2.0 μA-40°C to +85°C
VDD = 5.0V
2.0 8.0 μA +125°C
Legend: Shading of rows is to assist in readability of the table.
Note 1: The power-down current in Sleep mode does not depend on the oscillator type. Power-down current is measured with the
part in Sleep mode, with all I/O pins in high-impedance state and tied to V
DD or VSS and all features that add delta current
disabled (such as WDT, Timer1 Oscillator, BOR, etc.).
2: The supply current is mainly a function of operating voltage, frequency and mode. Other factors, such as I/O pin loading
and switching rate, oscillator type and circuit, internal code execution pattern and temperature, also have an impact on
the current consumption. The test conditions for all I
DD measurements in active operation mode are:
OSC1 = external square wave, from rail-to-rail; all I/O pins tri-stated, pulled to V
DD;
MCLR
= VDD; WDT enabled/disabled as specified.
3: For RC oscillator configurations, current through R
EXT is not included. The current through the resistor can be estimated
by the formula Ir = V
DD/2REXT (mA) with REXT in kΩ.
4: Standard low-cost 32 kHz crystals have an operating temperature range of -10°C to +70°C. Extended temperature
crystals are available at a much higher cost.