9. Module: MSSP
In SPI mode, the SDO output may change after the
inactive clock edge of the bit ‘0’ output. This may
affect some SPI components that read data over
300 ns after the inactive edge of SCK.
Work around
None
Date Codes that pertain to this issue:
All engineering and production devices.
10. Module: ECAN™ Technology
In Listen Only mode, the ECAN module may
persistently set the IRXIF and RXB0IF interrupt
flags and the RXFUL status flag, after receiving
129 or more consecutive error frames. In this case,
the flags can be cleared, but then will become set
again immediately and continuously without
receiving a bus message.
Work around
Place the ECAN module in Configuration mode
before receiving 129 consecutive error frames,
and then place it back into Listen Only mode.
Date Codes that pertain to this issue:
All engineering and production devices.
11. Module: 10-Bit Analog-to-Digital
Converter
When the AD clock source is selected as 2 TOSC or
RC (when ADCS2:ADCS0 = 000 or x11), in
extremely rare cases, the EIL (Integral Linearity
Error) and E
DL (Differential Linearity Error) may
exceed the data sheet specification at codes 511
and 512 only.
Work around
Select the AD clock source as 4 TOSC, 8 TOSC,
16 T
OSC, 32 TOSC or 64 TOSC and avoid selecting
2T
OSC or RC.