Datasheet

2010 Microchip Technology Inc. DS39616D-page 357
PIC18F2331/2431/4331/4431
FIGURE 26-15: I
2
C™ BUS START/STOP BITS TIMING
TABLE 26-15: I
2
C™ BUS START/STOP BITS REQUIREMENTS (SLAVE MODE)
FIGURE 26-16: I
2
C™ BUS DATA TIMING
Param.
No.
Symbol Characteristic Min Max Units Conditions
90 T
SU:STA Start Condition 100 kHz mode 4700 ns Only relevant for repeated
Start condition
Setup Time 400 kHz mode 600
91 T
HD:STA Start Condition 100 kHz mode 4000 ns After this period, the first
clock pulse is generated
Hold Time 400 kHz mode 600
92 TSU:STO Stop Condition 100 kHz mode 4000 ns
Setup Time 400 kHz mode 600
93 T
HD:STO Stop Condition 100 kHz mode 4700 ns
Hold Time 400 kHz mode 600
91
92
93
SCL
SDA
Start
Condition
Stop
Condition
90
90
91 92
100
101
103
106
107
109
109
110
102
SCL
SDA
In
SDA
Out