Datasheet
Table Of Contents
- Power-Managed Modes:
- Flexible Oscillator Structure:
- Peripheral Highlights:
- Peripheral Highlights (Continued):
- Special Microcontroller Features:
- Pin Diagrams
- Pin Diagrams (Continued)
- Pin Diagrams (Continued)
- Table of Contents
- Most Current Data Sheet
- Errata
- Customer Notification System
- 1.0 Device Overview
- 2.0 Guidelines for Getting Started with PIC18F Microcontrollers
- 3.0 Oscillator Configurations
- 4.0 Power-Managed Modes
- 5.0 Reset
- 5.1 RCON Register
- 5.2 Master Clear (MCLR)
- 5.3 Power-on Reset (POR)
- 5.4 Brown-out Reset (BOR)
- 5.5 Device Reset Timers
- 5.5.1 Power-up Timer (PWRT)
- 5.5.2 Oscillator Start-up Timer (OST)
- 5.5.3 PLL Lock Time-out
- 5.5.4 Time-out Sequence
- TABLE 5-2: Time-out in Various Situations
- FIGURE 5-3: Time-out Sequence on Power-up (MCLR Tied to Vdd, Vdd Rise < Tpwrt)
- FIGURE 5-4: Time-out Sequence on Power-up (MCLR Not Tied to Vdd): Case 1
- FIGURE 5-5: Time-out Sequence on Power-up (MCLR Not Tied to Vdd): Case 2
- FIGURE 5-6: Slow Rise Time (MCLR Tied to Vdd, Vdd Rise > Tpwrt)
- FIGURE 5-7: Time-out Sequence on POR w/PLL Enabled (MCLR Tied to Vdd)
- 5.6 Reset State of Registers
- 6.0 Memory Organization
- 6.1 Program Memory Organization
- 6.2 PIC18 Instruction Cycle
- 6.3 Data Memory Organization
- 6.4 Data Addressing Modes
- 6.5 Data Memory and the Extended Instruction Set
- 6.6 PIC18 Instruction Execution and the Extended Instruction Set
- 7.0 Flash Program Memory
- 7.1 Table Reads and Table Writes
- 7.2 Control Registers
- 7.3 Reading the Flash Program Memory
- 7.4 Erasing Flash Program Memory
- 7.5 Writing to Flash Program Memory
- 7.6 Flash Program Operation During Code Protection
- 8.0 Data EEPROM Memory
- 9.0 8 X 8 Hardware Multiplier
- 9.1 Introduction
- 9.2 Operation
- EXAMPLE 9-1: 8 x 8 Unsigned Multiply Routine
- EXAMPLE 9-2: 8 x 8 Signed Multiply Routine
- TABLE 9-1: Performance Comparison for Various Multiply Operations
- EQUATION 9-1: 16 x 16 Unsigned Multiplication Algorithm
- EXAMPLE 9-3: 16 x 16 Unsigned Multiply Routine
- EQUATION 9-2: 16 x 16 Signed Multiplication Algorithm
- EXAMPLE 9-4: 16 x 16 Signed Multiply Routine
- 10.0 Interrupts
- 11.0 I/O Ports
- 12.0 Timer0 Module
- 13.0 Timer1 Module
- 14.0 Timer2 Module
- 15.0 Timer3 Module
- 16.0 Capture/Compare/PWM (CCP) Modules
- Register 16-1: CCPxCON Register (CCP2 Module, CCP1 Module in 28-pin Devices)
- 16.1 CCP Module Configuration
- 16.2 Capture Mode
- 16.3 Compare Mode
- 16.4 PWM Mode
- 17.0 Enhanced Capture/ Compare/PWM (ECCP) Module
- Register 17-1: CCP1CON Register (ECCP1 Module, 40/44-pin Devices)
- 17.1 ECCP Outputs and Configuration
- 17.2 Capture and Compare Modes
- 17.3 Standard PWM Mode
- 17.4 Enhanced PWM Mode
- 17.4.1 PWM Period
- 17.4.2 PWM Duty Cycle
- 17.4.3 PWM Output Configurations
- 17.4.4 Half-Bridge Mode
- 17.4.5 Full-Bridge Mode
- 17.4.6 Programmable Dead-Band Delay
- 17.4.7 Enhanced PWM Auto-Shutdown
- 17.4.8 Start-up Considerations
- 17.4.9 Setup for PWM Operation
- 17.4.10 Operation in Power-Managed Modes
- 17.4.11 Effects of a Reset
- 18.0 Master Synchronous Serial Port (MSSP) Module
- 18.1 Master SSP (MSSP) Module Overview
- 18.2 Control Registers
- 18.3 SPI Mode
- 18.4 I2C Mode
- FIGURE 18-7: MSSP Block Diagram (I2C™ Mode)
- 18.4.1 Registers
- 18.4.2 Operation
- 18.4.3 Slave Mode
- EXAMPLE 18-2: Address Masking
- FIGURE 18-8: I2C™ Slave Mode Timing with SEN = 0 (Reception, 7-Bit Addressing)
- FIGURE 18-9: I2C™ Slave Mode Timing with SEN = 0 and ADMSK<5:1> = 01011 (Reception, 7-bit Addressing)
- FIGURE 18-10: I2C™ Slave Mode Timing (Transmission, 7-Bit Addressing)
- FIGURE 18-11: I2C™ Slave Mode Timing with SEN = 0 and ADMSK = 01001 (Reception, 10-bit Addressing)
- FIGURE 18-12: I2C™ Slave Mode Timing with SEN = 0 (Reception, 10-Bit Addressing)
- FIGURE 18-13: I2C™ Slave Mode Timing (Transmission, 10-Bit Addressing)
- 18.4.4 Clock Stretching
- 18.4.5 General Call Address Support
- 18.4.6 Master Mode
- 18.4.7 Baud Rate
- 18.4.8 I2C Master Mode Start Condition Timing
- 18.4.9 I2C Master Mode Repeated Start Condition Timing
- 18.4.10 I2C Master Mode Transmission
- 18.4.11 I2C Master Mode Reception
- 18.4.12 Acknowledge Sequence Timing
- 18.4.13 Stop Condition Timing
- 18.4.14 Sleep Operation
- 18.4.15 Effects of a Reset
- 18.4.16 Multi-Master Mode
- 18.4.17 Multi -Master Communication, Bus Collision and Bus Arbitration
- FIGURE 18-27: Bus Collision Timing for Transmit and Acknowledge
- FIGURE 18-28: Bus Collision During Start Condition (SDA Only)
- FIGURE 18-29: Bus Collision During Start Condition (SCL = 0)
- FIGURE 18-30: BRG Reset Due to SDA Arbitration During Start Condition
- FIGURE 18-31: Bus Collision During a Repeated Start Condition (Case 1)
- FIGURE 18-32: Bus Collision During Repeated Start Condition (Case 2)
- FIGURE 18-33: Bus Collision During a Stop Condition (Case 1)
- FIGURE 18-34: Bus Collision During a Stop Condition (Case 2)
- TABLE 18-4: Registers Associated with I2C™ Operation
- 19.0 Enhanced Universal Synchronous Asynchronous Receiver Transmitter (EUSART)
- Register 19-1: TXSTA: Transmit Status And Control Register
- Register 19-2: RCSTA: Receive Status And Control Register
- Register 19-3: BAUDCON: Baud Rate Control Register
- 19.1 Baud Rate Generator (BRG)
- 19.2 EUSART Asynchronous Mode
- 19.3 EUSART Synchronous Master Mode
- 19.4 EUSART Synchronous Slave Mode
- 20.0 10-Bit Analog-to-Digital Converter (A/D) Module
- Register 20-1: ADCON0: A/D Control Register 0
- Register 20-2: ADCON1: A/D Control Register 1
- Register 20-3: ADCON2: A/D Control Register 2
- FIGURE 20-1: A/D Block Diagram
- FIGURE 20-2: A/D Transfer Function
- FIGURE 20-3: Analog Input Model
- 20.1 A/D Acquisition Requirements
- 20.2 Selecting and Configuring Acquisition Time
- 20.3 Selecting the A/D Conversion Clock
- 20.4 Operation in Power-Managed Modes
- 20.5 Configuring Analog Port Pins
- 20.6 A/D Conversions
- 20.7 Discharge
- 20.8 Use of the CCP2 Trigger
- 21.0 Comparator Module
- Register 21-1: CMCON: Comparator Control Register
- 21.1 Comparator Configuration
- 21.2 Comparator Operation
- 21.3 Comparator Reference
- 21.4 Comparator Response Time
- 21.5 Comparator Outputs
- 21.6 Comparator Interrupts
- 21.7 Comparator Operation During Sleep
- 21.8 Effects of a Reset
- 21.9 Analog Input Connection Considerations
- 22.0 Comparator Voltage Reference Module
- 23.0 High/Low-Voltage Detect (HLVD)
- 24.0 Special Features of the CPU
- 24.1 Configuration Bits
- TABLE 24-1: Configuration Bits and Device IDs
- Register 24-1: CONFIG1H: Configuration Register 1 High (Byte Address 300001h)
- Register 24-2: CONFIG2L: Configuration Register 2 Low (Byte Address 300002h)
- Register 24-3: CONFIG2H: Configuration Register 2 High (Byte Address 300003h)
- Register 24-4: CONFIG3H: Configuration Register 3 High (Byte Address 300005h)
- Register 24-5: CONFIG4L: Configuration Register 4 Low (Byte Address 300006h)
- Register 24-6: CONFIG5L: Configuration Register 5 Low (Byte Address 300008h)
- Register 24-7: CONFIG5H: Configuration Register 5 High (Byte Address 300009h)
- Register 24-8: CONFIG6L: Configuration Register 6 Low (Byte Address 30000Ah)
- Register 24-9: CONFIG6H: Configuration Register 6 High (Byte Address 30000Bh)
- Register 24-10: CONFIG7L: Configuration Register 7 Low (Byte Address 30000Ch)
- Register 24-11: CONFIG7H: Configuration Register 7 High (Byte Address 30000Dh)
- Register 24-12: DEVID1: Device ID Register 1 for PIC18F2221/2321/4221/4321 Devices
- Register 24-13: DEVID2: Device ID Register 2 for PIC18F2221/2321/4221/4321 Devices
- 24.2 Watchdog Timer (WDT)
- 24.3 Two-Speed Start-up
- 24.4 Fail-Safe Clock Monitor
- 24.5 Program Verification and Code Protection
- 24.6 ID Locations
- 24.7 In-Circuit Serial Programming
- 24.8 In-Circuit Debugger
- 24.9 Single-Supply ICSP Programming
- 24.1 Configuration Bits
- 25.0 Instruction Set Summary
- 25.1 Standard Instruction Set
- 25.2 Extended Instruction Set
- 26.0 Development Support
- 27.0 Electrical Characteristics
- Absolute Maximum Ratings(†)
- 27.1 DC Characteristics: Supply Voltage PIC18F2221/2321/4221/4321 (Industrial) PIC18LF2221/2321/4221/4321 (Industrial)
- 27.2 DC Characteristics: Power-Down and Supply Current PIC18F2221/2321/4221/4321 (Industrial) PIC18LF2221/2321/4221/4321 (Industrial)
- 27.3 DC Characteristics: PIC18F2221/2321/4221/4321 (Industrial) PIC18LF2221/2321/4221/4321 (Industrial)
- 27.4 AC (Timing) Characteristics
- 27.4.1 Timing Parameter Symbology
- 27.4.2 Timing Conditions
- 27.4.3 Timing Diagrams and Specifications
- FIGURE 27-6: External Clock Timing (All Modes Except PLL)
- TABLE 27-6: External Clock Timing Requirements
- TABLE 27-7: PLL Clock Timing Specifications (Vdd = 4.2V to 5.5V)
- TABLE 27-8: AC Characteristics: Internal RC Accuracy
- FIGURE 27-7: CLKO and I/O Timing
- TABLE 27-9: CLKO and I/O Timing Requirements
- FIGURE 27-8: Reset, Watchdog Timer, Oscillator Start-up Timer and Power-up Timer Timing
- FIGURE 27-9: Brown-out Reset Timing
- TABLE 27-10: Reset, Watchdog Timer, Oscillator Start-up Timer, Power-up Timer and Brown-out Reset Requirements
- FIGURE 27-10: Timer0 and Timer1 External Clock Timings
- TABLE 27-11: Timer0 and Timer1 External Clock Requirements
- FIGURE 27-11: Capture/Compare/PWM Timings (All CCP Modules)
- TABLE 27-12: Capture/Compare/PWM Requirements (All CCP Modules)
- FIGURE 27-12: Parallel Slave Port Timing (PIC18F4221/4321)
- TABLE 27-13: Parallel Slave Port Requirements (PIC18F4221/4321)
- FIGURE 27-13: Example SPI Master Mode Timing (CKE = 0)
- TABLE 27-14: Example SPI Mode Requirements (Master Mode, CKE = 0)
- FIGURE 27-14: Example SPI Master Mode Timing (CKE = 1)
- TABLE 27-15: Example SPI Mode Requirements (Master Mode, CKE = 1)
- FIGURE 27-15: Example SPI Slave Mode Timing (CKE = 0)
- TABLE 27-16: Example SPI Mode Requirements (Slave Mode Timing, CKE = 0)
- FIGURE 27-16: Example SPI Slave Mode Timing (CKE = 1)
- TABLE 27-17: Example SPI Slave Mode Requirements (CKE = 1)
- FIGURE 27-17: I2C™ Bus Start/Stop Bits Timing
- TABLE 27-18: I2C™ Bus Start/Stop Bits Requirements (Slave Mode)
- FIGURE 27-18: I2C™ Bus Data Timing
- TABLE 27-19: I2C™ Bus Data Requirements (Slave Mode)
- FIGURE 27-19: Master SSP I2C™ Bus Start/Stop Bits Timing Waveforms
- TABLE 27-20: Master SSP I2C™ Bus Start/Stop Bits Requirements
- FIGURE 27-20: Master SSP I2C™ Bus Data Timing
- TABLE 27-21: Master SSP I2C™ Bus Data Requirements
- FIGURE 27-21: EUSART Synchronous Transmission (Master/slave) Timing
- TABLE 27-22: EUSART Synchronous Transmission Requirements
- FIGURE 27-22: EUSART Synchronous Receive (Master/Slave) Timing
- TABLE 27-23: EUSART Synchronous Receive Requirements
- TABLE 27-24: A/D Converter Characteristics
- FIGURE 27-23: A/D Conversion Timing
- TABLE 27-25: A/D Conversion Requirements
- 28.0 Packaging Information
- Appendix A: Revision History
- Appendix B: Device Differences
- Appendix C: Conversion Considerations
- Appendix D: Migration from Baseline to Enhanced Devices
- Appendix E: Migration From Mid-Range to Enhanced Devices
- Appendix F: Migration From High-End to Enhanced Devices
- INDEX
- The Microchip Web Site
- Customer Change Notification Service
- Customer Support
- Reader Response
- PIC18F2221/2321/4221/4321 Product Identification System
- Worldwide Sales and Service
© 2009 Microchip Technology Inc. DS39689F-page 181
PIC18F2221/2321/4221/4321 FAMILY
18.4.2 OPERATION
The MSSP module functions are enabled by setting
MSSP Enable bit, SSPEN (SSPCON1<5>).
The SSPCON1 register allows control of the I
2
C
operation. Four mode selection bits (SSPCON1<3:0>)
allow one of the following I
2
C modes to be selected:
•I
2
C Master mode clock
•I
2
C Slave mode (7-bit address)
•I
2
C Slave mode (10-bit address)
•I
2
C Slave mode (7-bit address) with Start and
Stop bit interrupts enabled
•I
2
C Slave mode (10-bit address) with Start and
Stop bit interrupts enabled
•I
2
C Firmware Controlled Master mode, slave is Idle
Selection of any I
2
C mode with the SSPEN bit set,
forces the SCL and SDA pins to be open-drain,
provided these pins are programmed to inputs by
setting the appropriate TRISC bits. To ensure proper
operation of the module, pull-up resistors must be
provided externally to the SCL and SDA pins.
18.4.3 SLAVE MODE
In Slave mode, the SCL and SDA pins must be config-
ured as inputs (TRISC<4:3> set). The MSSP module
will override the input state with the output data when
required (slave-transmitter).
The I
2
C Slave mode hardware will always generate an
interrupt on an address match. Address masking will
allow the hardware to generate an interrupt for more
than one address (up to 31 in 7-Bit Addressing mode
and up to 63 in 10-Bit Addressing mode). Through the
mode select bits, the user can also choose to interrupt
on Start and Stop bits
When an address is matched, or the data transfer after
an address match is received, the hardware auto-
matically will generate the Acknowledge (ACK
) pulse
and load the SSPBUF register with the received value
currently in the SSPSR register.
Any combination of the following conditions will cause
the MSSP module not to give this ACK
pulse:
• The Buffer Full bit, BF (SSPSTAT<0>), was set
before the transfer was received.
• The overflow bit, SSPOV (SSPCON1<6>), was
set before the transfer was received.
In this case, the SSPSR register value is not loaded
into the SSPBUF, but bit SSPIF (PIR1<3>) is set. The
BF bit is cleared by reading the SSPBUF register, while
bit SSPOV is cleared through software.
The SCL clock input must have a minimum high and
low for proper operation. The high and low times of the
I
2
C specification, as well as the requirement of the
MSSP module, are shown in timing parameter 100 and
parameter 101.
18.4.3.1 Addressing
Once the MSSP module has been enabled, it waits for
a Start condition to occur. Following the Start condition,
the 8 bits are shifted into the SSPSR register. All incom-
ing bits are sampled with the rising edge of the clock
(SCL) line. The value of register SSPSR<7:1> is
compared to the value of the SSPADD register. The
address is compared on the falling edge of the eighth
clock (SCL) pulse. If the addresses match and the BF
and SSPOV bits are clear, the following events occur:
1. The SSPSR register value is loaded into the
SSPBUF register.
2. The Buffer Full bit, BF, is set.
3. An ACK
pulse is generated.
4. MSSP Interrupt Flag bit, SSPIF (PIR1<3>), is
set (interrupt is generated, if enabled) on the
falling edge of the ninth SCL pulse.
In 10-Bit Addressing mode, two address bytes need to
be received by the slave. The five Most Significant bits
(MSbs) of the first address byte specify if this is a 10-bit
address. Bit R/W
(SSPSTAT<2>) must specify a write so
the slave device will receive the second address byte.
For a 10-bit address, the first byte would equal ‘11110
A9 A8 0’, where ‘A9’ and ‘A8’ are the two MSbs of the
address. The sequence of events for 10-bit address is as
follows, with steps 7 through 9 for the slave-transmitter:
1. Receive first (high) byte of address (bits SSPIF,
BF and UA (SSPSTAT<1>) are set).
2. Update the SSPADD register with second (low)
byte of address (clears bit UA and releases the
SCL line).
3. Read the SSPBUF register (clears bit BF) and
clear flag bit, SSPIF.
4. Receive second (low) byte of address (bits
SSPIF, BF and UA are set).
5. Update the SSPADD register with the first (high)
byte of address. If match releases SCL line, this
will clear bit UA.
6. Read the SSPBUF register (clears bit BF) and
clear flag bit, SSPIF.
7. Receive Repeated Start condition.
8. Receive first (high) byte of address (bits SSPIF
and BF are set).
9. Read the SSPBUF register (clears bit BF) and
clear flag bit, SSPIF.