2.13.3 FAIL-SAFE CONDITION CLEARING
The Fail-Safe condition is cleared by either one of the
following:
• Any Reset
• By toggling the SCS1 bit of the OSCCON register
Both of these conditions restart the OST. While the
OST is running, the device continues to operate from
the INTOSC selected in OSCCON. When the OST
times out, the Fail-Safe condition is cleared and the
device automatically switches over to the external clock
source. The Fail-Safe condition need not be cleared
before the OSCFIF flag is cleared.
2.13.4 RESET OR WAKE-UP FROM SLEEP
The FSCM is designed to detect an oscillator failure
after the Oscillator Start-up Timer (OST) has expired.
The OST is used after waking up from Sleep and after
any type of Reset. The OST is not used with the EC or
RC Clock modes so that the FSCM will be active as
soon as the Reset or wake-up has completed. When
the FSCM is enabled, the Two-Speed Start-up is also
enabled. Therefore, the device will always be executing
code while the OST is operating.
FIGURE 2-7: FSCM TIMING DIAGRAM
TABLE 2-6: SUMMARY OF REGISTERS ASSOCIATED WITH CLOCK SOURCES
Note: Due to the wide range of oscillator start-up
times, the Fail-Safe circuit is not active
during oscillator start-up (i.e., after exiting
Reset or Sleep). After an appropriate
amount of time, the user should check the
OSTS bit of the OSCCON register to verify
the oscillator start-up and that the system
clock switchover has successfully
completed.
Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Reset
Values on
page
CONFIG1H IESO FCMEN PCLKEN PLLEN FOSC3 FOSC2 FOSC1 FOSC0
296
INTCON GIE/GIEH PEIE/GIEL
TMR0IE INT0IE RABIE TMR0IF INT0IF RABIF 285
OSCCON IDLEN IRCF2 IRCF1 IRCF0 OSTS HFIOFS SCS1 SCS0 286
OSCTUNE INTSRC SPLLEN TUN5 TUN4 TUN3 TUN2 TUN1 TUN0 288
PIE2 OSCFIE
C1IE C2IE EEIE BCLIE USBIE TMR3IE —288
PIR2 OSCFIF C1IF C2IF EEIF BCLIF USBIF TMR3IF —288
T1CON
RD16 T1RUN T1CKPS1 T1CKPS0 T1OSCEN T1SYNC TMR1CS TMR1ON 105
Legend: x = unknown, u = unchanged, – = unimplemented locations read as ‘0’. Shaded cells are not used by oscillators.
Note 1: Other (non Power-up) Resets include MCLR
Reset and Watchdog Timer Reset during normal operation.
OSCFIF
System
Clock
Output
Sample Clock
Failure
Detected
Oscillator
Failure
Note: The system clock is normally at a much higher frequency than the sample clock. The relative frequencies in
this example have been chosen for clarity.
(Q)
Tes t
Test Test
Clock Monitor Output