Datasheet
PIC18(L)F1XK22
DS41365E-page 360 2009-2011 Microchip Technology Inc.
TABLE 25-16: I
2
C™ BUS START/STOP BITS REQUIREMENTS
FIGURE 25-22: I
2
C™ BUS DATA TIMING
Param
No.
Symbol Characteristic Min. Typ. Max. Units Conditions
SP90* T
SU:STA Start condition 100 kHz mode 4700 — — ns Only relevant for Repeated
Start condition
Setup time 400 kHz mode 600 — —
SP91* THD:STA Start condition 100 kHz mode 4000 — — ns After this period, the first
clock pulse is generated
Hold time 400 kHz mode 600 — —
SP92* T
SU:STO Stop condition 100 kHz mode 4700 — — ns
Setup time 400 kHz mode 600 — —
SP93 T
HD:STO Stop condition 100 kHz mode 4000 — — ns
Hold time 400 kHz mode 600 — —
* These parameters are characterized but not tested.
Note: Refer to Figure 25-7 for load conditions.
SP90
SP91
SP92
SP100
SP101
SP103
SP106
SP107
SP109
SP109
SP110
SP102
SCL
SDA
In
SDA
Out