Datasheet

PIC18(L)F1XK22
DS41365E-page 336 2009-2011 Microchip Technology Inc.
25.5 DC Characteristics: Primary Idle Supply Current, PIC18(L)F1XK22-I/E
(Industrial, Extended)
PIC18LF1XK22
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C TA +85°C for industrial
-40°C T
A +125°C for extended
PIC18F1XK22
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C T
A +85°C for industrial
-40°C T
A +125°C for extended
Param
No.
Device Characteristics Typ. Max. Units Conditions
D019
Supply Current (I
DD)
(1, 2, 4, 5)
70
105
A
-40°C to +125°C V
DD = 1.8V
F
OSC = 1 MHz
(PRI_IDLE mode,
EC Med Osc)
D019A
140
180
A
-40°C to +125°C V
DD = 3.0V
D019
80
120
A
-40°C to +125°C VDD = 2.3V
FOSC = 1 MHz
(PRI_IDLE mode,
EC Med Osc)
D019A
140
180
A
-40°C to +125°C VDD = 3.0V
D019B
151
230
A
-40°C to +125°C VDD = 5.0V
D020
1.0
1.8
mA
-40°C to +125°C V
DD = 1.8V
F
OSC = 16 MHz
(PRI_IDLEmode,
EC High Osc)
D020A
1.2
2.0
mA
-40°C to +125°C V
DD = 3.0V
D020
1.0
1.8
mA
-40°C to +125°C VDD = 2.3V
FOSC = 16 MHz
(PRI_IDLEmode,
EC High Osc)
D020A
1.2
2.0
mA
-40°C to +125°C VDD = 3.0V
D020B
1.4
2.1
mA
-40°C to +125°C VDD = 5.0V
D021
5.0
7.0
mA
-40°C to +125°C V
DD = 3.0V
F
OSC = 64 MHz
(PRI_IDLEmode,
EC High Osc)
D021
5.2
6.2
mA
-40°C to +125°C VDD = 3.0V
FOSC = 64 MHz
(PRI_IDLEmode,
EC High Osc)
D021A
5.3
6.3
mA
-40°C to +125°C VDD = 5.0V
* These parameters are characterized but not tested.
Note 1: The test conditions for all IDD measurements in active operation mode are: OSC1 = external square wave, from
rail-to-rail; all I/O pins tri-stated, pulled to V
DD; MCLR = VDD; WDT disabled.
2: The supply current is mainly a function of the operating voltage and frequency. Other factors, such as I/O pin
loading and switching rate, oscillator type, internal code execution pattern and temperature, also have an impact
on the current consumption.
3: For RC oscillator configurations, current through REXT is not included. The current through the resistor can be
extended by the formula I
R = VDD/2REXT (mA) with REXT in k
4: FVR and BOR are disabled.
5: When a single temperature range is provided for a parameter, the specification applies to both industrial and extended
temperature devices.