TABLE 27-16: I
2
C™ BUS START/STOP BITS REQUIREMENTS
FIGURE 27-20: I
2
C™ BUS DATA TIMING
Param
No.
Symbol Characteristic Min Typ Max Units Conditions
SP90* T
SU:STA Start condition 100 kHz mode 4700 ns Only relevant for Repeated
Start condition
Setup time 400 kHz mode 600
SP91* THD:STA Start condition 100 kHz mode 4000 ns After this period, the first
clock pulse is generated
Hold time 400 kHz mode 600
SP92* T
SU:STO Stop condition 100 kHz mode 4700 ns
Setup time 400 kHz mode 600
SP93 T
HD:STO Stop condition 100 kHz mode 4000 ns
Hold time 400 kHz mode 600
* These parameters are characterized but not tested.