Datasheet
PIC18F1230/1330
2009 Microchip Technology Inc. DS39758D-page 273
Supply Current (IDD)
(2)
PIC18LF1230/1330 250 497 A -40°C
V
DD = 2.0V
F
OSC = 1 MHz
(PRI_RUN,
EC oscillator)
260 497 A+25°C
250 497 A+85°C
PIC18LF1230/1330 550 750 A -40°C
V
DD = 3.0V480 750 A+25°C
460 750 A+85°C
All devices 1.2 3 mA -40°C
V
DD = 5.0V
1.1 3 mA +25°C
1.0 3 mA +85°C
Extended devices only 1.0 3.0 mA +125°C
PIC18LF1230/1330 0.72 1.93 mA -40°C
V
DD = 2.0V
F
OSC = 4 MHz
(PRI_RUN,
EC oscillator)
0.74 1.93 mA +25°C
0.74 1.93 mA +85°C
PIC18LF1230/1330 1.3 2.93 mA -40°C
V
DD = 3.0V1.3 2.93 mA +25°C
1.3 2.93 mA +85°C
All devices 2.7 5.93 mA -40°C
V
DD = 5.0V
2.6 5.93 mA +25°C
2.5 5.93 mA +85°C
Extended devices only 2.6 7.0 mA +125°C
Extended devices only 8.4 27.7 mA +125°C V
DD = 4.2V FOSC = 25 MHz
(PRI_RUN,
EC oscillator)
11 27.7 mA +125°C
V
DD = 5.0V
All devices 15 26 mA -40°C
V
DD = 4.2V
F
OSC = 40 MHz
(PRI_RUN,
EC oscillator)
16 25 mA +25°C
16 24 mA +85°C
All devices 21 39.3 mA -40°C
V
DD = 5.0V21 39.3 mA +25°C
21 39.3 mA +85°C
23.2 DC Characteristics: Power-Down and Supply Current
PIC18F1230/1330 (Industrial)
PIC18LF1230/1330 (Industrial) (Continued)
PIC18LF1230/1330
(Industrial)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C T
A +85°C for industrial
PIC18F1230/1330
(Industrial, Extended)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C T
A +85°C for industrial
-40°C T
A +125°C for extended
Param
No.
Device Typ Max Units Conditions
Note 1: The power-down current in Sleep mode does not depend on the oscillator type. Power-down current is measured
with the part in Sleep mode, with all I/O pins in high-impedance state and tied to V
DD or VSS and all features that
add delta current disabled (such as WDT, Timer1 oscillator, BOR, etc.).
2: The supply current is mainly a function of operating voltage, frequency and mode. Other factors, such as I/O pin
loading and switching rate, oscillator type and circuit, internal code execution pattern and temperature, also have
an impact on the current consumption.
The test conditions for all I
DD measurements in active operation mode are:
OSC1 = external square wave, from rail-to-rail; all I/O pins tri-stated, pulled to V
DD or VSS;
MCLR
= VDD; WDT enabled/disabled as specified.
3: Low-power Timer1 oscillator selected.
4: BOR and LVD enable internal band gap reference. With both modules enabled, current consumption will be less
than the sum of both specifications.