Datasheet

PIC18F1230/1330
2009 Microchip Technology Inc. DS39758D-page 275
Supply Current (IDD)
(2)
PIC18LF1230/1330 65 112 A -40°C
VDD = 2.0V
F
OSC = 1 MHz
(PRI_IDLE mode,
EC oscillator)
65 112 A+25°C
70 112 A+85°C
PIC18LF1230/1330 120 237 A -40°C
V
DD = 3.0V120 237 A+25°C
130 237 A+85°C
All devices 300 360 A -40°C
V
DD = 5.0V
240 360 A+25°C
300 360 A+85°C
Extended devices only 320 865 A +125°C
PIC18LF1230/1330 260 427 A -40°C
V
DD = 2.0V
F
OSC = 4 MHz
(PRI_IDLE mode,
EC oscillator)
255 427 A+25°C
270 427 A+85°C
PIC18LF1230/1330 420 740 A -40°C
V
DD = 3.0V430 740 A+25°C
450 740 A+85°C
All devices 0.9 1.23 mA -40°C
V
DD = 5.0V
0.9 1.23 mA +25°C
0.9 1.23 mA +85°C
Extended devices only 1 1.2 mA +125°C
Extended devices only 2.8 10.7 mA +125°C V
DD = 4.2V FOSC = 25 MHz
(PRI_IDLE mode,
EC oscillator)
4.3 10.7 mA +125°C V
DD = 5.0V
All devices 6.0 9.5 mA -40°C
V
DD = 4.2V
F
OSC = 40 MHz
(PRI_IDLE mode,
EC oscillator)
6.2 9.0 mA +25°C
6.6 8.6 mA +85°C
All devices 8.1 17.3 mA -40°C
V
DD = 5.0V9.1 17.3 mA +25°C
8.3 17.3 mA +85°C
23.2 DC Characteristics: Power-Down and Supply Current
PIC18F1230/1330 (Industrial)
PIC18LF1230/1330 (Industrial) (Continued)
PIC18LF1230/1330
(Industrial)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C T
A +85°C for industrial
PIC18F1230/1330
(Industrial, Extended)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C T
A +85°C for industrial
-40°C T
A +125°C for extended
Param
No.
Device Typ Max Units Conditions
Note 1: The power-down current in Sleep mode does not depend on the oscillator type. Power-down current is measured
with the part in Sleep mode, with all I/O pins in high-impedance state and tied to V
DD or VSS and all features that
add delta current disabled (such as WDT, Timer1 oscillator, BOR, etc.).
2: The supply current is mainly a function of operating voltage, frequency and mode. Other factors, such as I/O pin
loading and switching rate, oscillator type and circuit, internal code execution pattern and temperature, also have
an impact on the current consumption.
The test conditions for all I
DD measurements in active operation mode are:
OSC1 = external square wave, from rail-to-rail; all I/O pins tri-stated, pulled to V
DD or VSS;
MCLR
= VDD; WDT enabled/disabled as specified.
3: Low-power Timer1 oscillator selected.
4: BOR and LVD enable internal band gap reference. With both modules enabled, current consumption will be less
than the sum of both specifications.