Datasheet

Table Of Contents
PIC16LF1904/6/7
DS41569A-page 172 Preliminary 2011 Microchip Technology Inc.
18.3.1 AUTO-BAUD DETECT
The EUSART module supports automatic detection
and calibration of the baud rate.
In the Auto-Baud Detect (ABD) mode, the clock to the
BRG is reversed. Rather than the BRG clocking the
incoming RX signal, the RX signal is timing the BRG.
The Baud Rate Generator is used to time the period of
a received 55h (ASCII “U”) which is the Sync character
for the LIN bus. The unique feature of this character is
that it has five rising edges including the Stop bit edge.
Setting the ABDEN bit of the BAUDCON register starts
the auto-baud calibration sequence (Figure 18.3.2).
While the ABD sequence takes place, the EUSART
state machine is held in Idle. On the first rising edge of
the receive line, after the Start bit, the SPBRGL begins
counting up using the BRG counter clock as shown in
Table 18-6. The fifth rising edge will occur on the
RX/DT pin at the end of the eighth bit period. At that
time, an accumulated value totaling the proper BRG
period is left in the SPBRGH:SPBRGL register pair, the
ABDEN bit is automatically cleared, and the RCIF
interrupt flag is set. A read operation on the RCREG
needs to be performed to clear the RCIF interrupt.
RCREG content should be discarded. When calibrating
for modes that do not use the SPBRGH register the
user can verify that the SPBRGL register did not
overflow by checking for 00h in the SPBRGH register.
The BRG auto-baud clock is determined by the BRG16
and BRGH bits as shown in Table 18-6. During ABD,
both the SPBRGH and SPBRGL registers are used as
a 16-bit counter, independent of the BRG16 bit setting.
While calibrating the baud rate period, the SPBRGH
and SPBRGL registers are clocked at 1/8th the BRG
base clock rate. The resulting byte measurement is the
average bit time when clocked at full speed.
FIGURE 18-6: AUTOMATIC BAUD RATE CALIBRATION
Note 1: If the WUE bit is set with the ABDEN bit,
auto-baud detection will occur on the byte
following the Break character (see
Section 18.3.3 “Auto-Wake-up on
Break”).
2: It is up to the user to determine that the
incoming character baud rate is within the
range of the selected BRG clock source.
Some combinations of oscillator frequency
and EUSART baud rates are not possible.
3: During the auto-baud process, the
auto-baud counter starts counting at 1.
Upon completion of the auto-baud
sequence, to achieve maximum accu-
racy, subtract 1 from the
SPBRGH:SPBRGL register pair.
TABLE 18-6: BRG COUNTER CLOCK
RATES
BRG16 BRGH
BRG Base
Clock
BRG ABD
Clock
00F
OSC/64 FOSC/512
01F
OSC/16 FOSC/128
10F
OSC/16 FOSC/128
11 FOSC/4 FOSC/32
Note: During the ABD sequence, SPBRGL and
SPBRGH registers are both used as a
16-bit counter, independent of BRG16
setting.
BRG Value
RX/DT pin
ABDEN bit
RCIF bit
bit 0
bit 1
(Interrupt)
Read
RCREG
BRG Clock
Start
Auto Cleared
Set by User
XXXXh 0000h
Edge #1
bit 2
bit 3
Edge #2
bit 4
bit 5
Edge #3
bit 6
bit 7
Edge #4
Stop bit
Edge #5
001Ch
Note 1: The ABD sequence requires the EUSART module to be configured in Asynchronous mode.
SPBRGL
XXh
1Ch
SPBRGH
XXh
00h
RCIDL