Datasheet
2006-2012 Microchip Technology Inc. DS41291G-page 265
PIC16F882/883/884/886/887
FIGURE 17-9: CAPTURE/COMPARE/PWM TIMINGS (ECCP)
TABLE 17-6: CAPTURE/COMPARE/PWM REQUIREMENTS (ECCP)
Standard Operating Conditions (unless otherwise stated)
Operating Temperature -40°C T
A +125°C
Param
No.
Sym. Characteristic Min. Typ† Max. Units Conditions
CC01* TccL CCP1 Input Low Time No Prescaler 0.5T
CY + 20 — — ns
With Prescaler 20 — — ns
CC02* TccH CCP1 Input High Time No Prescaler 0.5T
CY + 20 — — ns
With Prescaler 20 — — ns
CC03* TccP CCP1 Input Period 3TCY + 40
N
— — ns N = prescale
value (1, 4 or
16)
* These parameters are characterized but not tested.
† Data in “Typ” column is at 5V, 25°C unless otherwise stated. These parameters are for design guidance
only and are not tested.
Note: Refer to Figure 17-3 for load conditions.
(Capture mode)
CC01 CC02
CC03
CCP1