2002 Microchip Technology Inc. DS30221B-page 137
PIC16F872
FIGURE 14-16: A/D CONVERSION TIMING
TABLE 14-10: A/D CONVERSION REQUIREMENTS
131
130
132
BSF ADCON0, GO
Q4
A/D CLK
A/D DATA
ADRES
ADIF
GO
SAMPLE
OLD_DATA
SAMPLING STOPPED
DONE
NEW_DATA
(T
OSC/2)
(1)
987 210
Note: If the A/D clock source is selected as RC, a time of T
CY is added before the A/D clock starts. This allows the
SLEEP instruction to be executed.
1 TCY
. . .
. . .
Param
No.
Sym Characteristic Min Typ Max Units Conditions
130 T
AD A/D Clock Period Standard(F)1.6——µsTOSC based, VREF 3.0V
Extended(LF)3.0——
µsTOSC based, VREF 2.0V
Standard(F) 2.0 4.0 6.0
µs A/D RC mode
Extended(LF) 3.0 6.0 9.0
µs A/D RC mode
131 T
CNV Conversion Time (not including S/H time)
(Note 1)
12 TAD
132 TACQ Acquisition Time (Note 2)
10*
40
µs
µs The minimum time is the
amplifier settling time. This may
be used if the "new" input volt-
age has not changed by more
than 1 LSb (i.e., 20.0 mV @
5.12V) from the last sampled
voltage (as stated on C
HOLD).
134 T
GO Q4 to A/D Clock Start TOSC/2 §— If the A/D clock source is
selected as RC, a time of T
CY is
added before the A/D clock
starts. This allows the
SLEEP
instruction to be executed.
* These parameters are characterized but not tested.
Data in "Typ" column is at 5V, 25°C unless otherwise stated. These parameters are for design guidance only and are not
tested.
§ This specification ensured by design.
Note 1: ADRES register may be read on the following T
CY cycle.
2: See Section 10.1 for min. conditions.