Datasheet
PIC16F84A
DS35007C-page 54 2001-2013 Microchip Technology Inc.
9.3.2 TIMING CONDITIONS
The temperature and voltages specified in Table 9-1
apply to all timing specifications unless otherwise
noted. All timings are measured between high and low
measurement points as indicated in Figure 9-4.
Figure 9-5 specifies the load conditions for the timing
specifications.
TABLE 9-1: TEMPERATURE AND VOLTAGE SPECIFICATIONS - AC
FIGURE 9-4: PARAMETER MEASUREMENT INFORMATION
FIGURE 9-5: LOAD CONDITIONS
AC CHARACTERISTICS
Standard Operating Conditions (unless otherwise stated)
Operating temperature 0°C T
A +70°C for commercial
-40°C T
A +85°C for industrial
Operating voltage V
DD range as described in DC specifications (Section 9.1)
0.9 VDD (High)
0.1 V
DD (Low)
0.8 VDD RC
0.3 V
DD XTAL
OSC1 Measurement Points I/O Port Measurement Points
0.15 V
DD RC
0.7 V
DD XTAL
(High)
(Low)
Load Condition 1 Load Condition 2
Pin
RL
CL
VSS
VDD/2
VSS
CL
Pin
R
L = 464
C
L = 50 pF for all pins except OSC2
15 pF for OSC2 output