Datasheet
PIC16F7X7
DS30498C-page 28 2004 Microchip Technology Inc.
2.2.2.8 PCON Register
The Power Control (PCON) register contains flag bits
to allow differentiation between a Power-on Reset
(POR), a Brown-out Reset (BOR), a Watchdog Reset
(WDT) and an external MCLR
Reset.
REGISTER 2-8: PCON: POWER CONTROL/STATUS REGISTER (ADDRESS 8Eh)
Note: BOR is unknown on POR. It must be set
by the user and checked on subsequent
Resets to see if BOR is clear, indicating a
brown-out has occurred. The BOR status
bit is not predictable if the brown-out circuit
is disabled (by clearing the BOREN bit in
the Configuration Word register).
U-0 U-0 U-0 U-0 U-0 R/W-1 R/W-0 R/W-1
— — — — — SBOREN POR BOR
bit 7 bit 0
bit 7-3 Unimplemented: Read as ‘0’
bit 2 SBOREN: Software Brown-out Reset Enable bit
If BORSEN in Configuration Word 2 is a ‘
1’ and BOREN in Configuration Word 1 is ‘0’:
1 = BOR enabled
0 = BOR disabled
bit 1 POR
: Power-on Reset Status bit
1 = No Power-on Reset occurred
0 = A Power-on Reset occurred (must be set in software after a Power-on Reset occurs)
bit 0 BOR
: Brown-out Reset Status bit
1 = No Brown-out Reset occurred
0 = A Brown-out Reset occurred (must be set in software after a Brown-out Reset occurs)
Legend:
R = Readable bit W = Writable bit U = Unimplemented bit, read as ‘0’
-n = Value at POR ‘1’ = Bit is set ‘0’ = Bit is cleared x = Bit is unknown