Datasheet

2004 Microchip Technology Inc. DS30498C-page 171
PIC16F7X7
REGISTER 15-2: CONFIGURATION WORD REGISTER 2 (ADDRESS 2008h)
U-1 U-1 U-1 U-1 U-1 U-1 U-1 R/P-1 U-1 U-1 U-1 U-1 R/P-1 R/P-1
BORSEN IESO FCMEN
bit 13 bit 0
bit 13-7 Unimplemented: Read as1
bit 6 BORSEN: Brown-out Reset Software Enable bit
Refer to Configuration Word Register 1, bit 6 for the function of this bit.
bit 5-2 Unimplemented: Read as ‘1
bit 1 IESO: Internal External Switchover bit
1 = Internal External Switchover mode enabled
0 = Internal External Switchover mode disabled
bit 0 FCMEN: Fail-Safe Clock Monitor Enable bit
1 = Fail-Safe Clock Monitor enabled
0 = Fail-Safe Clock Monitor disabled
Legend:
R = Readable bit W = Writable bit U = Unimplemented bit, read as ‘0’