Datasheet

2010-2012 Microchip Technology Inc. DS41413C-page 363
PIC12(L)F1822/PIC16(L)F1823
TABLE 30-8: PIC12(L)F1822/16(L)F1823 A/D CONVERTER (ADC) CHARACTERISTICS:
(1), (2), (3)
TABLE 30-9: PIC12(L)F1822/16(L)F1823 A/D CONVERSION REQUIREMENTS
Standard Operating Conditions (unless otherwise stated)
Operating temperature T
A 25°C
Param
No.
Sym. Characteristic Min. Typ† Max. Units Conditions
AD01 N
R Resolution 10 bit
AD02 E
IL Integral Error ±1.7 LSb VREF = 3.0V
AD03 E
DL Differential Error ±1 LSb No missing codes
V
REF = 3.0V
AD04 E
OFF Offset Error ±2.5 LSb VREF = 3.0V
AD05 E
GN Gain Error ±2.0 LSb VREF = 3.0V
AD06 V
REF Reference Voltage
(4)
1.8 VDD VVREF = (VREF+ minus VREF-)
AD07 V
AIN Full-Scale Range VSS —VREF V
AD08 Z
AIN Recommended Impedance of
Analog Voltage Source
—— 10k Can go higher if external 0.01F capacitor is
present on input pin.
* These parameters are characterized but not tested.
Data in “Typ” column is at 3.0V, 25°C unless otherwise stated. These parameters are for design guidance only and are not
tested.
Note 1: Total Absolute Error includes integral, differential, offset and gain errors.
2: The A/D conversion result never decreases with an increase in the input voltage and has no missing codes.
3: When ADC is off, it will not consume any current other than leakage current. The power-down current specification
includes any such leakage from the ADC module.
4: ADC Reference Voltage (
REF+) is the selected input, VREF+ pin, VDD pin or the FVR Buffer 1. When the FVR is selected
as the reference input, the FVR Buffer 1 output selection must be 2.048V or 4.096V (ADFVR<1:0> = 1x).
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C T
A +125°C
Param
No.
Sym. Characteristic Min. Typ† Max. Units Conditions
AD130* T
AD A/D Clock Period 1.0 9.0 sTOSC-based
A/D Internal RC Oscillator
Period
1.0 2.5 6.0 s ADCS<1:0> = 11 (ADRC mode)
AD131 T
CNV Conversion Time (not including
Acquisition Time)
(1)
—11—TAD Set GO/DONE bit to conversion
complete
AD132* T
ACQ Acquisition Time 5.0 s
* These parameters are characterized but not tested.
Data in “Typ” column is at 3.0V, 25°C unless otherwise stated. These parameters are for design guidance only and are not
tested.
Note 1: The ADRES register may be read on the following T
CY cycle.