17.2 ADC Operation
17.2.1 STARTING A CONVERSION
To enable the ADC module, the ADON bit of the
ADCON0 register must be set to a ‘1. Setting the
GO/DONE
bit of the ADCON0 register to a ‘1’ will clear
the ADRESH and ADRESL registers and start the
Analog-to-Digital conversion.
17.2.2 COMPLETION OF A CONVERSION
When the conversion is complete, the ADC module will:
Clear the GO/DONE
bit
Set the ADIF Interrupt Flag bit
17.2.3 TERMINATING A CONVERSION
When a conversion is terminated before completion by
clearing the GO/DONE
bit then the partial results are
discarded and the results in the ADRESH and ADRESL
registers from the previous conversion remain
unchanged.
17.2.4 ADC OPERATION DURING SLEEP
The ADC module can operate during Sleep. This
requires the ADC clock source to be set to the F
RC
option. When the FRC oscillator source is selected, the
ADC waits one additional instruction before starting the
conversion. This allows the SLEEP instruction to be
executed, which can reduce system noise during the
conversion. If the ADC interrupt is enabled, the device
will wake-up from Sleep when the conversion
completes. If the ADC interrupt is disabled, the ADC
module is turned off after the conversion completes,
although the ADON bit remains set.
When the ADC clock source is something other than
F
RC, a SLEEP instruction causes the present conver-
sion to be aborted and the ADC module is turned off,
although the ADON bit remains set.
17.2.5 AUTO-CONVERSION TRIGGER
The Auto-conversion Trigger of the CCP module allows
periodic ADC measurements without software
intervention. When a rising edge of the selected source
occurs, the GO/DONE
bit is set by hardware and the
Timer1 counter resets to zero.
The Auto-conversion Trigger source is selected with
the TRIGSEL<3:0> bits of the ADCON2 register.
Using the Auto-conversion Trigger does not assure
proper ADC timing. It is the user’s responsibility to
ensure that the ADC timing requirements are met.
Auto-conversion sources are:
CCP1
CCP2
PSMC1
PSMC2
Note: The GO/DONE bit should not be set in the
same instruction that turns on the ADC.
Refer to
Section 17.2.6 “A/D Conversion
Procedure”
.
Note: A device Reset forces all registers to their
Reset state. Thus, the ADC module is
turned off and any pending conversion is
terminated.