2011-2012 Microchip Technology Inc. Preliminary DS41579D-page 151
PIC16(L)F1782/3
TABLE 17-1: ADC CLOCK PERIOD (TAD) VS. DEVICE OPERATING FREQUENCIES
FIGURE 17-2: ANALOG-TO-DIGITAL CONVERSION T
AD CYCLES
ADC Clock Period (TAD) Device Frequency (FOSC)
ADC
Clock Source
ADCS<2:0> 32 MHz 20 MHz 16 MHz 8 MHz 4 MHz 1 MHz
FOSC/2 000 62.5ns
(2)
100 ns
(2)
125 ns
(2)
250 ns
(2)
500 ns
(2)
2.0 s
F
OSC/4 100 125 ns
(2)
200 ns
(2)
250 ns
(2)
500 ns
(2)
1.0 s4.0 s
F
OSC/8 001 0.5 s
(2)
400 ns
(2)
0.5 s
(2)
1.0 s2.0 s 8.0 s
(3)
FOSC/16 101 800 ns 800 ns 1.0 s2.0 s4.0 s 16.0 s
(3)
FOSC/32 010 1.0 s1.6 s2.0 s4.0 s 8.0 s
(3)
32.0 s
(3)
FOSC/64 110 2.0 s3.2 s4.0 s 8.0 s
(3)
16.0 s
(3)
64.0 s
(3)
FRC x11 1.0-6.0 s
(1,4)
1.0-6.0 s
(1,4)
1.0-6.0 s
(1,4)
1.0-6.0 s
(1,4)
1.0-6.0 s
(1,4)
1.0-6.0 s
(1,4)
Legend: Shaded cells are outside of recommended range.
Note 1: The FRC source has a typical TAD time of 1.6 s for VDD.
2: These values violate the minimum required TAD time.
3: For faster conversion times, the selection of another clock source is recommended.
4: The ADC clock period (TAD) and total ADC conversion time can be minimized when the ADC clock is derived from the
system clock F
OSC. However, the FRC oscillator source must be used when conversions are to be performed with the
device in Sleep mode.
TAD1
TAD2
TAD3
TAD4 TAD5
TAD6 TAD7
TAD8 TAD11
Set GO
TAD9 TAD10
TCY - TAD
GO bit is cleared, ADIF bit is set,
holding capacitor is connected to analog input.
b2
b11
b8
b7
b6
b5
b4
b3
b10
b9
On the following cycle:
TAD13TAD12
b0b1
TAD15TAD14
sign
Input
Sample
Conversion
starts
Holding cap disconnected
from input
bit
TAD17TAD16
Holding cap.
discharge