Datasheet

Table Of Contents
2011-2013 Microchip Technology Inc. DS41458C-page 329
PIC16(L)F1526/7
FIGURE 25-20: I
2
C™ BUS START/STOP BITS TIMING
FIGURE 25-21: I
2
C™ BUS DATA TIMING
Note: Refer to Figure 25-5 for load conditions.
SP91
SP92
SP93
SCLx
SDAx
Start
Condition
Stop
Condition
SP90
TABLE 25-13: I
2
C™ BUS START/STOP BITS REQUIREMENTS
Standard Operating Conditions (unless otherwise stated)
Operating Temperature -40°C TA +125°C
Param.
No.
Symbol Characteristic Min. Typ. Max. Units Conditions
SP90* TSU:STA Start condition 100 kHz mode 4700 ns Only relevant for
repeated Start condition
Setup time 400 kHz mode 600
SP91* T
HD:STA Start condition 100 kHz mode 4000 ns After this period, the first
clock pulse is generated
Hold time 400 kHz mode 600
SP92* T
SU:STO Stop condition 100 kHz mode 4700 ns
Setup time 400 kHz mode 600
SP93 T
HD:STO Stop condition 100 kHz mode 4000 ns
Hold time 400 kHz mode 600
* These parameters are characterized but not tested.
Note: Refer to Figure 25-5 for load conditions.
SP90
SP91
SP92
SP100
SP101
SP103
SP106
SP107
SP109
SP109
SP110
SP102
SCLx
SDAx
In
SDAx
Out