2011-2013 Microchip Technology Inc. DS41458C-page 325
PIC16(L)F1526/7
FIGURE 25-15: USART SYNCHRONOUS RECEIVE (MASTER/SLAVE) TIMING
TABLE 25-11: USART SYNCHRONOUS RECEIVE REQUIREMENTS
Standard Operating Conditions (unless otherwise stated)
Operating Temperature -40°C TA +125°C
Param.
No.
Symbol Characteristic Min. Max. Units Conditions
US125 TDTV2CKL SYNC RCV (Master and Slave)
Data-hold before CK
(DT hold time) 10 ns
US126 T
CKL2DTL Data-hold after CK (DT hold time) 15 ns
Note: Refer to Figure 25-5 for load conditions.
US125
US126
CK
DT