Datasheet

Table Of Contents
PIC16(L)F1526/7
DS41458C-page 322 2011-2013 Microchip Technology Inc.
TABLE 25-7: ANALOG-TO-DIGITAL CONVERTER (ADC) CHARACTERISTICS
(1,2,3)
TABLE 25-8: ADC CONVERSION REQUIREMENTS
Standard Operating Conditions (unless otherwise stated)
Operating Temperature Tested at 25°C
Param
No.
Sym. Characteristic Min. Typ† Max. Units Conditions
AD01 NR Resolution 10 bit
AD02 E
IL Integral Error ±1 ±1.7 LSb VREF = 3.0V
AD03 E
DL Differential Error ±1 ±1 LSb No missing codes
V
REF = 3.0V
AD04 E
OFF Offset Error ±1 ±2.5 LSb VREF = 3.0V
AD05 E
GN Gain Error ±1 ±2.0 LSb VREF = 3.0V
AD06 V
REF Reference Voltage
(4)
1.8 VDD VVREF = (VREF+ minus VREF-)
AD07 V
AIN Full-Scale Range VSS —VREF V
AD08 Z
AIN Recommended Impedance of
Analog Voltage Source
—— 10k Can go higher if external 0.01F capacitor is
present on input pin.
Data in “Typ” column is at 3.0V, 25°C unless otherwise stated. These parameters are for design guidance only and are not
tested.
Note 1: Total Absolute Error includes integral, differential, offset and gain errors.
2: The ADC conversion result never decreases with an increase in the input voltage and has no missing codes.
3: ADC VREF is from external VREF, VDD pin or FVR, whichever is selected as reference input.
4: ADC Reference Voltage (Ref+) is the selected reference input, VREF+ pin, VDD pin or the FVR Buffer1. When the FVR is
selected as the reference input, the FVR Buffer1 output selection must be 2.048V or 4.096V (ADFVR<1:0> =
1x).
Standard Operating Conditions (unless otherwise stated)
Operating Temperature -40°C TA +125°C
Param
No.
Sym. Characteristic Min. Typ† Max. Units Conditions
AD130* TAD ADC Clock Period 1.0 9.0 sFOSC-based
ADC Internal RC Oscillator
Period
1.0 2.0 6.0
s ADCS<2:0> = x11
(ADC FRC mode)
AD131 T
CNV Conversion Time (not including
Acquisition Time)
(1)
—11—TAD Set GO/DONE bit to conversion
complete
AD132* T
ACQ Acquisition Time 5.0 s
AD133 T
HCD Holding Capacitor Disconnect
0.5*TAD + 40 ns
(0.5*T
AD + 40 ns)
to
(1.5*T
AD + 40 ns)
ADCS<2:0>
x11
(FOSC-based)
ADCS<2:0> =
x11
(ADC FRC mode)
* These parameters are characterized but not tested.
Data in “Typ” column is at 3.0V, 25°C unless otherwise stated. These parameters are for design guidance only and are not
tested.
Note 1: The ADRES register may be read on the following TCY cycle.