Datasheet

PIC16(L)F1516/7/8/9
DS41452C-page 308 2010-2012 Microchip Technology Inc.
FIGURE 25-20: I
2
C™ BUS START/STOP BITS TIMING
TABLE 25-13: I
2
C™ BUS START/STOP BITS REQUIREMENTS
Param
No.
Symbol Characteristic Min. Typ Max. Units Conditions
SP90* TSU:STA Start condition 100 kHz mode 4700 ns Only relevant for Repeated
Start condition
Setup time 400 kHz mode 600
SP91* THD:STA Start condition 100 kHz mode 4000 ns After this period, the first
clock pulse is generated
Hold time 400 kHz mode 600
SP92* T
SU:STO Stop condition 100 kHz mode 4700 ns
Setup time 400 kHz mode 600
SP93 THD:STO Stop condition 100 kHz mode 4000 ns
Hold time 400 kHz mode 600
* These parameters are characterized but not tested.
Note: Refer to Figure 25-5 for load conditions.
SP91
SP92
SP93
SCLx
SDAx
Start
Condition
Stop
Condition
SP90