2010-2013 Microchip Technology Inc. DS40001452D-page 171
PIC16(L)F1516/7/8/9
20.1.5 CAPTURE DURING SLEEP
Capture mode depends upon the Timer1 module for
proper operation. There are two options for driving the
Timer1 module in Capture mode. It can be driven by the
instruction clock (F
OSC/4), or by an external clock source.
When Timer1 is clocked by F
OSC/4, Timer1 will not
increment during Sleep. When the device wakes from
Sleep, Timer1 will continue from its previous state.
Capture mode will operate during Sleep when Timer1
is clocked by an external clock source.
20.1.6 ALTERNATE PIN LOCATIONS
This module incorporates I/O pins that can be moved to
other locations with the use of the alternate pin function
register APFCON. To determine which pins can be
moved and what their default locations are upon a
Reset, see
Section 12.1 “Alternate Pin Function” for