Information

PIC16(L)F1508/1509
DS80536D-page 4 2012-2013 Microchip Technology Inc.
3. Module: Fixed Voltage Reference (FVR)
3.1 Gain Amplifier Output
When using the FVR module, if the gain amplifier
outputs are set via the CDAFVR or ADFVR bits in
FVRCON while the module is disabled (FVREN =
0), the internal oscillator frequency may shift,
device current consumption can increase, and a
Brown-out Reset may occur.
Work around
Set the FVREN bit of FVRCON to enable the
module prior to adjusting the amplifier output
selections with the CDAFVR and ADFVR bits. If
switching from the 4x output setting to the 1x
output setting, select the 2x output setting as an
intermediary step. Always set the amplifier output
selections to off (’00’) before disabling the FVR
module.
Affected Silicon Revisions
A0 A2
X