Datasheet

PIC16(L)F1503
DS41607A-page 308 Preliminary 2011 Microchip Technology Inc.
FIGURE 28-17: I
2
C™ BUS DATA TIMING
TABLE 28-11: I
2
C™ BUS START/STOP BITS REQUIREMENTS
Param
No.
Symbol Characteristic Min. Typ Max. Units Conditions
SP90* TSU:STA Start condition 100 kHz mode 4700 ns Only relevant for Repeated
Start condition
Setup time 400 kHz mode 600
SP91* T
HD:STA Start condition 100 kHz mode 4000 ns After this period, the first
clock pulse is generated
Hold time 400 kHz mode 600
SP92* TSU:STO Stop condition 100 kHz mode 4700 ns
Setup time 400 kHz mode 600
SP93 THD:STO Stop condition 100 kHz mode 4000 ns
Hold time 400 kHz mode 600
* These parameters are characterized but not tested.
Note: Refer to Figure 28-4 for load conditions.
SP90
SP91
SP92
SP100
SP101
SP103
SP106
SP107
SP109
SP109
SP110
SP102
SCLx
SDAx
In
SDAx
Out